6. TROUBLESHOOTING
Problem:
The motor does not react to commands
Cause:
Thermal cut-out was activated
Solution:
Wait for 10-20 minutes
Problem:
Curtain fins do not close fully
Cause:
The curtain is blocked in the guides
Solution:
Check the roller blind guides and curtain slats
Problem:
Curtain fins do not close fully
Cause:
Roller blind too long
Solution:
Shorten the roller blind curtain
Problem:
The motor stops on its own
Cause:
The curtain is blocked in the guides
Solution:
Check the roller blind guides and curtain slats
Problem:
The motor does not detect obstacles when
moving down.
Cause:
Wrong hangers used.
Solution:
Install blocking hangers.
WARNING! Pauses between individual presses of the blind
switch buttons should be at least 1 second long!
7.
MOTOR SELECTION TABLE
TORQUE