- 3 - 

   

Step 14: 

Connect the power for start up. 

           

    Step 15: 

Do not remove the uv lamp from the chamber when applying the electrical power 

   

Step 16: 

UV systems are designed for continuous operation and frequent switching will reduce ultra-violet radiation and 

    service life. Do not electrically cycle the uv unit more then 3 on/off cycles in a 24 hour period. 
 

System Operation 

a.

Water Quality Guidelines

 

  The Ultraviolet Disinfection System is intended for the use with visually clear water, not colored, cloudy or turbid.

 

 

 

Ambient Water Temperature: 2-45

 

 

Iron: <0.3ppm (0.3mg/l)     

 

Hardness: <7gpg (120mg/l) 

 

Turbidity: <1NTU   

 

Manganese: 0.05ppm (0.05mg/l) 

 

UV Transmittance: >75% 

b. 

Recheck the installation before plug the sterilizer into power.   

c.

 Do not proceed to install the equipment when UV Lamp or Sleeve Tube is broken, purchase a replacement and continue.

 

d.

 Ultraviolet Disinfection System is designed for continuous operation and frequent switching will reduce Ultraviolet     

radiation and service life.   

e. 

If this unit falls into the water, turn main power off and then retrieve it. Do not attempt to use this sterilizer if it has been submerged. 

f. 

Do not operate this unit if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or been damaged in any 

manner.   

g.

 The UV system should be installed after the filter on the return line.     

h.

 Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures below freezing 

for extended periods of time. 

 

Important Safeguards 

a

   

b.

 

  UV light is not visible to human eye, but harmful to eyes and skin. Never look directly at the light tube while device is in 

operation. Do not remove the UV Lamp from the Reactor Chamber when applying electrical power.

 

Wear SAFETY GOGGLES if 

you need to look necessary. 

c.

 

Basic safety precautions should always be followed to reduce the risk of fire, electric shock. Make sure the leakage protection 

switch is installed before use. 

d. 

Please do not touch the UV lamp directly in case of burning.   

 

System Maintenance 

a

. Testing monthly or before each use. 

b

. Lamp replacement is recommended every 9000 hours of operation.

 

After 9000 hours, the lamp may still light, but the UV intensity 

has diminished.   

c

. Cleaning of the quartz sleeve once 3-6 months with alcohol or a mild detergent. 

 

   

 

                       

Warranty for uv chamber 2 years, uv lamp and quartz sleeve changer yearly 

 

Note: To save the energy, turn off the power and water supply if you do not use the equipment for a long time. 

 

                                 

                                                                                                                           

 