Industrial Test Systems Pool eXact EZ Quick Start Manual Download Page 3

3

We developed the revolutionary Pool eXact

®

 EZ photometer to easily 

maintain pool water quality. It uses state of the art technology to 

produce lab-quality results poolside. The Pool eXact

®

 EZ photometer 

is waterproof (IP-67) and has a built-in sample cell to enhance 

usability. 

MeTer OVerVIeW

SAMPLE CELL
Built-in plastic 4ml cell for 
collecting your water sample

LCD DISPLAY
Displays results and 
test name

READ BUTTON
Starts test timer

MENU BUTTON
Cycles through test 
menus

BASE
Install/replace batteries here 
(IP67 rated waterproof)

RESULT 

UNITS

LOW 

BATTERY

lcD DisplAy

ZERO/ON BUTTON
Turns the meter on and 
creates a baseline for 
your water testing

CELL COVER
Covers the cell for 
mixing and bright light 
situations

*Combined Chlorine DPD-3 Test requires Free Chlorine DPD-1 (486637) to be run first.

For resellers and distributors - products sold in case quantities (12 units per case).                                     

PARAMETER/TEST

No.

PART #

RANGE

1
2
3
4
5
6
7

For use in accordance with U.S. Patent No. 7,333,194,

U.S. Patent No. 7,491,546, South African Patent No. 2007/0628,

EU Patent #1,725,864, and International Patent Appln. No. PCT/US2005/033985

TESTS

eXact Pool Water Refill Kit
Alkalinity, Total
Calcium (as CaCO3)
Chlorine, Free (DPD-1)
Chlorine, Combined (DPD-3)*
Chlorine, Total (DPD-4)
Cyanuric Acid
pH

486211
486641
486629
486637
486638
486670

481652-II
486639-II

N/A

11 - 200 ppm
19 - 550 ppm

0.05 - 12 ppm
0.05 - 12 ppm
0.05 - 12 ppm

3 - 110 ppm

6.0 - 8.5

as below

100

50

100
100
100

60

100

R052814

Pool eXact

®

 EZ Photometer Specifications

Summary of Contents for Pool eXact EZ

Page 1: ...1 QuicK stArt guiDe ADVANCED PHOTOMETER SYSTEM DigitAl AccurAcy For better pool cAre ...

Page 2: ...rewdriver to remove the screw from the base of your Pool eXact EZ Photometer 2 Remove the base 3 Install 4 new AAA batteries as illustrated inside your Pool eXact EZ Photometer We recommend using high quality batteries 4 Replace the base firmly with pressure while tightening the screw The meter will power on automatically COnTenTS WelCOMe Welcome Kit Contents 2 Battery Installation 2 Meter Overvie...

Page 3: ...er testing CELL COVER Covers the cell for mixing and bright light situations Combined Chlorine DPD 3 Test requires Free Chlorine DPD 1 486637 to be run first For resellers and distributors products sold in case quantities 12 units per case PARAMETER TEST No PART RANGE 1 2 3 4 5 6 7 For use in accordance with U S Patent No 7 333 194 U S Patent No 7 491 546 South African Patent No 2007 0628 EU Patent...

Page 4: ...p Micro e g Free Chlorine DPD 1 from the bottle or foil packet and set in a dry convenient place Turn meter on by pressing ZERO ON The display will indicate current MENU followed by the last test result Press and re press MENU until the display shows the parameter to be tested e g CL1 matches CL on bottle STAnDArD STrIP MeThOD 1 2 3 FIll DIP reAD CL1 ...

Page 5: ...ple cell and simultaneously press READ This starts the 20 SECOND countdown timer During this time move the strip in a gentle back and forth motion approx 2 strokes sec Remove and discard the strip after 1 on the display disappears The cursor will move across the display while the meter prepares to measure the sample reAD result displayed After testing is complete rinse the sample cell immediately ...

Page 6: ...acket Set it in a dry convenient place With the DPD 1 sample still in the cell press ZERO ON The display reads 0 PPM Dip the eXact Strip Micro CL DPD 3 into the CELL and simultaneously press READ This starts another 20 SECOND countdown timer During this time move the strip in a gentle back and forth motion approx 2 strokes sec Remove and discard the strip after 1 on the display disappears FIll DIP...

Page 7: ...er measures the sample reAD the Combined Chlorine value displayed If you require a value for Total Chlorine press READ again and record result displayed After testing is complete rinse the sample cell immediately FIll DIP reAD 11 12 SCAn FOr TeST DeMO VIDeO ...

Page 8: ...nd re press MENU until the display shows the parameter CY5 Rinse the sample cell 3 times with the water sample you will be testing and fill the sample cell Using the cell cover cap the sample cell and press ZERO ON The cursor will move across the display followed by 0 PPM 1 2 3 4 FIll DIP reAD CY5 CYAnUrIC ACID TeST ...

Page 9: ...inger over cap and mix the sample by turning the meter upside down repetitively during the 20 second countdown When timer displays 1 place meter on flat surface upright and the meter begins a 60 second count up timing at the end of which the cursor will move across the display while the meter prepares to measure the sample Record result displayed this result is automatically stored in CY5 Rinse th...

Page 10: ...eXact EZ photometer uses a 525nm wavelength The eXact Strip Micro CL DPD 1 uses the same reagents and proportions and the resulting solution pH is maintained between 6 2 and 6 5 as specified by AWWA method 4500 Cl G The USEPA does not approve commercial DPD delivery systems The eXact Strip Micro CL DPD 1 for Free Chlorine and the eXact Strip Micro CL DPD 3 for Combined Chlorine or the eXact Strip ...

Page 11: ...in the bottle These should be discarded Using these strips may give unreliable results Meter is not compatible for use with powder pillows tablets or liquids from other manufacturers Dip strip for entire countdown Each eXact Strip Micro is valid for ONLY one test Discard strip after use Dry the outside of the meter before storage Remove batteries before storing for prolonged periods Store the mete...

Page 12: ...e at http www sensafe com product registration form Personal data is kept confidential The eXact photometer is warranted to be free from defects in materials and workmanship for a period of two 2 years from the date of purchase by the customer ITS will repair or replace at its discretion product which is deemed to be faulty due to manufacturing defect Warranty does not cover product damage caused ...