INDURA EXTLRE Manual Download Page 2

Back plate

housing

EXTLRE 
Only

page 2

INSTALLATION and MOUNTING

1

2

TO OPEN THE UNIT:

Open the unit and service the if necessary.  When closing, 
ensure that wires are not pinched and proceed to screw all 
screws (10x). 

Unscrew exterior screws from the product with a screwdriver. 

screws

A. 

Use code-approved connectors to connect input leads inside 

J-box [See label on wire pair for positive and negative polarity 
colors].

B

. On the mounting plate, open the desired keyhole junction-

box knockouts.

C

. Route input connector through center hole in mounting plate.

D

. Taking care not to pinch wires or connectors dressed inside 

junction box, secure mounting plate to junction box screws. 
NOTE: to ensure proper engagement of the mounting plate 
latches to the housing, DO NOT OVER-TIGHTEN THE 
SCREWS.

E

. The unit, as shipped, is designed to be mounted on a 

smooth rigid surface to allow foam pad to tightly seal.  If 
mounted to other surface, the installer should apply silicone  
to the top and sides of the unit to seal and prevent water 
ingress from the back of the unit.

Junction box mounting:

-Some details shown below may vary-

1

Mounting plate 

Part # 912-00033-001 

Rev.G, 01/2021

© 2020, Acuity Brands Lighting, inc.

All Rights Reserved.

IMPORTANT: 

Provide DC power supply from 5V through 20V for SP640L, 7V through 30V for SP1100L and SP2200L, un-

switched circuit used for emergency lighting. 

WARNING:  

During installation of remotes, opposite polarity wires from main unit to remote units must 

NOT be connected to 

each other or 

connected to ground.  Failure to do so will lead to failure of the main unit.

NOTE

The maximum mounting height with tilt and swivel lamp heads are shown below to meet the minimum illumination 

requirements of NFPA 101 (Current Life Safety Code).

LIFE SAFETY SOLUTIONS

TEL:  800-705-SERV (7378)  

www.lithonia.com

[email protected]

Junction boxes

accommodated:

4” Square

4” Octagon

3-

1/2” Round or 

Octagon

Single Gang Box

INDRE model 
without bubble

INDRE/EXTLRE SP640L 

31.9/28.5 ft

INDRE/EXTLRE SP1100L 

47.2/41.4 ft

INDRE/EXTLRE SP2200L 

66.3/62 ft

Summary of Contents for EXTLRE

Page 1: ...JURY This product may have sharp edges Wear gloves to prevent cuts or abrasions when removing from carton handling installing and maintaining this product WARNING Do not exceed fixtures ambient temper...

Page 2: ...taller should apply silicone to the top and sides of the unit to seal and prevent water ingress from the back of the unit Junction box mounting Some details shown below may vary 1 Mounting plate Part...

Page 3: ...DC input to the remote units See label on wire pair for positive and negative polarity colors Single Driver Board Wiring diagram Remote Lamp DC input to the remote units See label on wire pair for pos...

Page 4: ...oes not cause harmful interference LAMP AIMING 1 With lamp heads aimed begin by tightening the nut until the gasket is fully compressed Torque spec 20 in lbs 2 With unit open loosen the nut and screw...

Page 5: ...ener bordes afilados Use guantes para evitar cortes o abrasiones al extraer el producto de la caja manipularlo instalarlo o repararlo ADVERTENCIA No exceda la temperatura ambiente de los accesorios 40...

Page 6: ...ficie el instalador debe aplicar silicona en la parte superior y los lados de la unidad para sellar y evitar la entrada de agua desde la parte posterior de la unidad Montaje de la caja de conexi n Alg...

Page 7: ...ERV 7378 www lithonia com techsupport emergency acuitybrands com L mpara remota Entrada CC a las unidades remotas Consulte la etiqueta en el par de cables para saber cu les son los colores de polarida...

Page 8: ...mple con el T tulo 47 de la FCC Parte 15 Subparte B Este dispositivo no causa interferencia da ina Tornillo Empaquetadora AYUDANDO A LA L MPARA 1 Con los cabezales de la l mpara apuntados comience por...

Page 9: ...NER DES BLESSURES CORPORELLES AVERTISSEMENT RISQUE DE BLESSURES CORPORELLES Ce produit peut avoir des bords tranchants Portez des gants pour viter les coupures ou les corchures lorsque vous sortez le...

Page 10: ...autre surface l installateur doit appliquer du silicone sur le dessus et les c t s de l unit pour sceller et emp cher la p n tration d eau par l arri re de l unit Montage du bo tier de raccordement C...

Page 11: ...a com techsupport emergency acuitybrands com Lampe distance Entr e CC vers les unit s distance Voir l tiquette sur la paire de fils pour les couleurs de polarit positive et n gative Simple circuit imp...

Page 12: ...unications Commission Cet appareil est conforme la FCC titre 47 partie 15 sous partie B Cet appareil ne cause pas de brouillage pr judiciable Vis Joint LAMPE VISANT 1 Avec les t tes de lampe orient es...

Reviews: