01.05.2014 (release date and version)
_________________________________________________________________________________
FB TS AS7 01 ICG® Standard Operating Procedure | released by ICG® Service Department 9
4) Handlebar assembly
a) Bring handlebar to its maximum vertical position. Do not remove warning tape on slider prior
to handlebar is mounted to the upper slider.
b)
ATTENTION!
Place the flat handlebar support under the console bracket as shown on the
picture.
Mount handlebar weldment using the M8 x 25 x 1.0P counter sunk hex. socket bolt from
beneath using a straight shaft (round head) 6mm Allen key socket wrench.
Maximum torque: 25-30 Nm.
c) Mount the plastic end cap on the lower handlebar slider and check the horizontal and
vertical adjustment as described in the separate SOP (FB TS HB7 01).
a) b)
c)