Assemble the manifold block or the protective cover with
6 pcs of screws M12.
Test of the rotator function.
Attach the rotation ports (R, R) in stator upper to a
hydraulic powerpack.
Run for 20 seconds in each direction.
Maximum oil flow: 35 l/min
Pressure test of the grapple function.
Attach the grapple ports (G, G0) in stator upper to a
hydraulic powerpack.
Pressurize to 20 MPa for 20 seconds.
Note! The grapple outlets (G, G0) on the manifold
block have to be sealed by steel plugs before testing!