The following instructions are directed at the qualified
installer so that the installation and maintenance
proceedures may be followed in the most professional and
expert manner possible.
Important: Unplug the electrical connection before
performing any maintenance or regulation upkeep
work.

Installation of built-in stove tops
The electric hobs are prepared with protection degree
against excessive heating of Y type, it is therefore possible
to instal them next to furniture which is higher than the
working board. For a correct installation of the cooking
top the following precautions must be followed:
a) The hob may be located in a kitchen, a kitonen/diner

or bed sitting room, but no in a bathroom or shower
room.

b) The hoods must be installed according to the

requirements in the hood handbook.

c) The dimensions of the cutout for the appliance must

be those indicated in the figure. Clamps are provided
to fasten the cooktop to counters measuring from 20
to 40 mm in thickness. To fasten the cooktop securely,
it is recommended that all the clamps be used.

555 mm.

55 mm.

475 mm.

Fastening Clamps - Assembly Diagram

20

30

Clamp Position for

Clamp Position for

H=20mm top

H=30mm top

Front

40

Clamp Position for
H=40mm top

Back

N.B: Use the clamps contained in the "accessory kit."
d) In case a wooden panel should be fitted under the top

for insulation, it will have be fitted at a minimum distance
of 20 mm from the inferior part of the top.

Important: When installing the hob on a built-in oven, the
oven should be placed on two wooden strips; in the case
of a joining cabinet surface, remember to leave a space
of at least 45 x 560 mm at the back.

560 mm.

45 mm.

When installing on a built-in oven without forced ventilation,
ensure that there are air inlets and outlets for ventilating
the interior of the cabinet adequately. Assembly examples
are given in figs.

Electrical connection for electric hob
The following installation procedure must be carried out
by a qualified electrician.
Important: the cooker must be connected to the mains
by a switched (double pole) cooker outlet correctly fused
with a capacity appropriate to that shown on the hob Rating
Plate. All electrical wiring from the consumer unit to the
appliance, via the switched double pole cooker outlet, must
be of an acceptable type and current rating as above. The
supply cord, type H05 VV-F 3x2.5mm

2

, must be positioned

so that it never reaches at any point a temperature 50°C
higher than the room temperature. The electrical
installation must comply with the IEE Regulations, Building
Regulation & local By-Lays.
WARNING: THIS APPLIANCE MUST BE EARTHED.
In the case of installation over a built-in electric oven the
electrical hook-up of the stove top and that of the oven
should be separate, for reasons of safety as well as for
ease of eventual removal of the oven.

Supply cable installation
The electrcic hobs are supplied without cable. Use a cable:

H05 VV-F 3x2.5mm

2

Open the terminal box by removing the "V" screw and
taking off the cover.

The wires in the mains lead are coloured in accordance

Summary of Contents for P 604 GB

Page 1: ...Electric built in cooking tables Instructions for installation and use P 604 GB ...

Page 2: ...Electric built in cooking tables Instructions for installation and use ...

Page 3: ... be regulated by turning the corresponding knob in the clockwise or counter clockwise direction to any one of the 6 different settings 0 Off 1 Low 2 5 Medium 6 High Congratualtions on choosing an Indesit appliance which you will find is dependable and easy to use We recommend that you read this manual for best performance and to extend the life of your appliance Thank you The section entitled Prac...

Page 4: ...large quantities of food minestrone 4 For roasting average 5 For roasting above average 6 For browning and reaching a boil in a short time Before using the hot plates for the first time you should heat them at maximum temperature for approximately 4 minutes without any pans During this initial stage their protective coating hardens and reaches its maximum resistance Practical Advice Use of the hob...

Page 5: ...aving the electric hobs on without cookware on top of them Closing the glass top if present while the electrical hot plates are still hot Trying to install or repair the appliance without the assistance of qualified personnel The assistance of qualified personnel must be called upon in the following cases Installation in accordance with the manufacturer s instructions When in doubt about the opera...

Page 6: ...m from the inferior part of the top Important When installing the hob on a built in oven the oven should be placed on two wooden strips in the case of a joining cabinet surface remember to leave a space of at least 45 x 560 mm at the back 560 mm 45 mm When installing on a built in oven without forced ventilation ensure that there are air inlets and outlets for ventilating the interior of the cabin...

Page 7: ...h the V screw F V 1 2 3 4 5 Technical characteristics Voltage and supply frequency and power 230V 50 60 Hz Max absorption 7000 W Mod Indesit P 604 GB This appliance conforms with the following European Economic Community directives 73 23 EEC of 19 02 73 Low Voltage and subsequent modifications 89 336 EEC of 03 05 89 Electromagnetic Compatibility and subsequent modifications 93 68 EEC of 22 07 93 a...

Page 8: ...Merloni Elettrodomestici Viale Aristide Merloni 47 60044 Fabriano Italy Tel 39 0732 6611 Fax 39 0732 662501 www merloni com Piano incasso 04 12 00 195028880 00 Xerox Business Services Docutech ...