5.5. TROUBL
E
SHOOTING:
ANALYSIS
PROBL
E
M
Fails to s
w
itch on.
Compressor fails to start
Compressor runs but ap-
pliance fails to cool.
Compressor unable to
start.
-
Check voltage on socket outlet.
-
Check power cord.
-
Check continuity of windings
-
Check operation of Klixon relay.
-
Faulty PCB.
-
Appliance set to OFF.
-
Compressor is cold - check refrigerant charge.
-
Compressor is very hot - Check for traces of oil or refrigerant circuit is
blocked.
-
Check for possible faulty compressor.
-
Faulty Klixon relay.
-
Faulty compressor.
-
Mains voltage very low.
-
Drain hole blocked.
-
Container or wrapping paper touching refrigeration wall.
-
Condensate collection bowl broken.
-
Water drain tube incorrectly positioned.
-
Condensate collection bowl not in contact with compressor.
-
Faulty thermostat.
-
I
ncorrectly positioned thermostat.
-
Unsuitable installation on electrical Klixon.
-
Door fails to close properly.
-
Refrigerant circuit insufficient charge or blocked.
-
Damaged compressor.
-
Check Thermostat/PCB.
-
No magnet in door.
-
Faulty PCB.
-
Door is distorted.
-
Check display cable.
-
Check display PCB.
-
Evaporator coil clogged with ice.
-
Check fusible link.
-
Check heating elements.
-
Chilled air suction fan motor.
-
I
ce has formed in the duct between the refrigerator and freezer compartments.
- Check temperature sensors.
Water under crisper dra
w
-
ers.
Water on floor.
Compressor fails to stop.
Compressor fails to start.
Door open alarm sounds
continuously.
Display s
w
itches off in-
termittently.
For No-Frost appliances:
the compartments are in-
sufficiently cold.
For No-Frost appliances: the
refrigerator compartment
does not cool properly.
Refrigerator compartment too
cold - food tends to freeze.