Indesit KG 6407 BG/G Instructions For Installation And Use Manual Download Page 3

3

Installation instructions

All instruction on the following pages must be carried out
by a competent person (corgi registered) in compliance
with gas safety (installation and use) regulation 1984.
Important: disconnect the cooker from the electrycity
and gas supply when any adjustment, etc.

Positioning
Important:  
this unit may be installed and used only in
permanently ventilated rooms according to the British
Standards Codes Of Practice: B.S. 6172/B.S. 5440, Par. 2
and B.S. 6891 Current Editions. The following requirements
must be observed:
a) The cooker should not be installed in a bed sitting room

with a volume of less than 20m

3

. If it is installed in a

room of volume less than 5m

3

 an air vent of effective

area of 110cm

2

 is required, if it is installed in a room of

volume between 5m

3

 and 10m

3

 a supplementary

airvent area of 50cm

2

 is required, while if the volume

exceeds 11m

3

 no airvent is required. However, if the

room has a door or a window vhich opens directly to
the outside no air vent is required even when the volu-
me is between 5m

3

 and 11m

3

.

b) During prolonged use of the appliance you may

consider it necessary to open a window to the outside
to improve ventilation.

c) If there are other fuel burning appliances in the same

room, B.S.5440 Part 2 Current Edition, should, be
consulted to determine the requisite air vent
requirements.

Installation of the cooker
The cooker is prepared with protection degree against
excessive heating of type X, the appliance can therefore
be installed next to cabinets, provided the height does not
exceed that of the hob. If the cooker is placed touching
walls or sides of neighbouring cabinets, these must be
capable of withstanding a temperature rise of 60°C above
room temperature. Levelling feet supplied with the cooker,
can be fitted to the cooker to accomodate uneven floors.
See fitting instruction on feet packing. For a correct
installation of the cooker the following precautions must
be followed:
a) The cooker may be located in a kitchen, a kitonen/

diner or bed sitting room, but not in a bathroom or
shower room.

b) The furniture units next to the cooker, that is higher

than the working boards, must be placed at least
110 mm from the edge of the board. Curtains must not
be fitted immediately behind the cooker or within
110 mm. of the sides of the cooker.

c) The hoods must be installed according to the

requirements in the hood handbook.

d) Wall cabinets may be fitted in line with the sides of the

base units, providing that the lower edge of the wall
cabinet is a minimum of 420 mm. above the worktop.
The minimum distance combustible material kitchen
units can be fitted directly above the worktop is 700
mm. (see Fig. A)

e) The wall in contact with the back of the cooker must

be of flameproof material.

f) The cooker is fitted with the a safety chain that must

be attached to a hook, secured to the wall behind the
appliance (see Fig. B).

HOOD

420

Min.

min. 

650

 mm. with hood

min. 

700

 mm. without hood

mm.

600

Min.

mm.

420

Min.

mm.

Fig. A

Fig. B

Connecting the gas
The cooker should be connected to the gas-suply by a
corgi registered installer. During installation of this product
it is essential to fit an approved gas tap to isolate the supply
from the appliance for the convenience of any subsequent
removal or servicing. Connection of the appliance to the
gas mains or liquid gas must be carried out according to
the prescribed regulation in force, and only after it is
ascertained that it is adaptable to the type of gas to be
used. If not, follow the instructions indicated in the
paragraph headed “Adaptation to different gas types”. In
the case of connection to liquid gas, by tank, use pressure
regulators that conform to the regulation in force. The gas
supply must be connected to the right of the appliance.
Be sure that the hose does not pass through the rear of
the cooker touching hot parts.
Important: make sure the supply pressure conforms with
the values shown in the table entitled “Caracteristics of
the burners and nozzles”.
When the cooker is installed between cabinets (recessed),
the gas connection must be effected by an approved
flexible hose with bayonet fitting (BS 669 Current Edition).
The gas inlet for the cookers is a threaded G 1/2 gas
female fitting.

Connecting the gas supply
To make the connection, a flexible hose should be used
corresponding to the current gas regulations which are:

the hose must never be at any point in its lenght in
contact with the “hot” parts of the cooker;

the hose must never be longer than 1.5 metre;

the hose must not be subject to any tension or torsional
stress and it must not have any excessively narrow
curves or bottlenecks;

the hose must be easy to inspect along its entire lenght
to check its condition;

the hose must always be in good condition, never
attempt to repair.

Important: the installation must comply with gas safety
(installation and use) regulations 1984. In all cases for the
above, by low, a qualified, corgi approved engineer must
be called for installation.

Summary of Contents for KG 6407 BG/G

Page 1: ...KG 6407 WG G KG 6407 BG G KG 6407 XG G Cooker with gas oven and gas grill Instructions for installation and use ...

Page 2: ...th the utmost caution do not pull the power supply cable or the appliance itself to disconnect the plug from the socket do not expose the appliance to weather agents raing sun etc do not allow unsupervised children or inexperienced persons to use the appliance 13 Always switch off the electrical supply to the cooker and allow it to cool down before carrying out any cleaning operations etc 14 In th...

Page 3: ... handbook d Wall cabinets may be fitted in line with the sides of the base units providing that the lower edge of the wall cabinet is a minimum of 420 mm above the worktop The minimum distance combustible material kitchen units can be fitted directly above the worktop is 700 mm see Fig A e The wall in contact with the back of the cooker must be of flameproof material f The cooker is fitted with th...

Page 4: ...ce with the following code Green Yellow Earth Blue Neutral Brown Live As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your plug proceed as follows Connect Green Yellow wire to terminal marked E or or coloured Green or Green Yellow Connect Brown wire to terminal marked L or coloured Red Connect Blue wire to terminal marked N o...

Page 5: ...2 To regulate the amount of air to the burner use the values indicated in table 1 Air Regulation for Burners Once the adjustment is made fix hose C with the screw B Fig F Table 1 Regulating air a mm Burner Butane Propane Natural Gas G20 Fast large Front right Fast Rear left Medium Rear right Medium Front left 11 13 13 13 0 0 0 0 Oven burner Grill burner Side A 1 Side A 1 Side B 0 Side A 0 2 Minimu...

Page 6: ...ed pressure it is necessary to fit a suitable pressure regulator onto the inlet pipe in compliance with current National Regulations relative to regulators for channelled gas Burner and nozzles characteristics Table 2 Liquid Gas Natural Gas Burner Diameter mm Thermal power kW p c s By pass 1 100 mm Nozzle 1 100 mm Flow g h Nozzle 1 100 mm Flow l h Nomin Reduc Front Right 90 3 30 0 70 42 90 240 236...

Page 7: ...and subsequent 93 68 EEC of 22 07 93 and subsequent A Hob surface B Gas burners C Control panel D Top grate E Drip tray or cooking plate F Oven shelf G Inner glass H Oven door I Drawer J Instant electronic lighting device only on certain models A D C F B E I H G CONTROL PANEL 1 6 5 1 4 OVEN GRILL 4 3 2 ON OFF 7 1 2 1 3 5 9 h 7 1 Timer 2 Elec Ignition Switch only on certain models 3 Rotisserie Swit...

Page 8: ...range of temperatures is shown below OVEN TEMPERATURE GUIDE Cas Mark Descript Temperature C F 1 4 1 2 COOL 121 250 1 2 1 VERY SLOW 121 235 250 275 1 2 SLOW 135 149 275 300 2 3 VERY MODERATE 149 177 300 350 4 MODERATE 190 375 5 MODERATE HOT 204 400 6 7 HOT 218 233 425 450 8 9 VERY HOT 246 260 475 500 h MAX This temperature is reached automatically and kept constant by the knob controlled thermostat...

Page 9: ...ponds with the reference mark for maximum and minimum To obtain these settings turn the knob counter clockwise with respect to the off position To turn off the burner turn the knob clockwise until it stops corresponding again with the symbol Gas cook top electronic ignition 2 only a few models This device operates when a sliht pressure is applied on the botton 2 marked with To light a specific bur...

Page 10: ...and fish use low temperatures 150 C 175 C When red meat must be superficially well cooked but succulent inside it is advisable to start with a high temperature 200 220 C for a short time and then to reduce it at a later point Generally speaking the more meat there is the lower the temperature and the longer the cooking time should be Place the meat in the centre of the grid and put a spill tray un...

Page 11: ...le warm vinegar in models with glass covers the covers are cleaned with hot water and use of rough cloths or abrasives is to be avoided Important periodically check the wear of the gas hose and substitute it if there are any defects we recommended changing it every year Replacing the oven light bulb Either pull out the plug if it is accessible or disconnect the oven from the mains by turning off t...

Page 12: ...viale Aristide Merloni 47 60044 Fabriano tel 0732 6611 telex 560196 fax 0732 662954 www Merloni com Cucina con forno gas e grill gas 02 99 195013897 06 Xerox Business Services Docutech ...