background image

3

Do not store explosive or flammable

substances (e.g. gasoline or aerosol cans) inside or

near the appliance - risk of fire.

Use pots and pans with bottoms the same

width as that of the burners or slightly larger (see

specific table). Make sure pots on the grates do

not protrude beyond the edge of the hob.

Improper use of the grids can result in damage

to the hob: do not position the grids upside down

or slide them across the hob.

Do not let the burner flame extend beyond the edge of the pan.
Do not use : Cast iron griddles, ollar stones, terracotta pots and pans.

Heat diffusers such as metal mesh, or any other types. Two burners

simultaneously for one receptacle (e.g. Fish kettle).
Should particular local conditions of the delivered gas make the ignition

of burner difficult, it is advisable to repeat the operation with the knob

turned to small flame setting.

In case of installation of a hood above the cooktop, please refer to the

hood instructions for the correct distance.
The protective rubber feet on the grids represent a chocking hazard for

young children. After removing the grids, please ensure that all the feet

are correctly fitted.

INSTALLATION

The appliance must be handled and installed

by two or more persons - risk of injury. Use

protective gloves to unpack and install - risk of

cuts.

The electrical and gas connections must

comply with local regulations.

Installation, including water supply (if any),

electrical connections and repairs must be carried

out by a qualified technician. Do not repair or

replace any part of the appliance unless specifically

stated in the user manual. Keep children away from

the installation site. After unpacking the appliance,

make sure that it has not been damaged during

transport. In the event of problems, contact the

dealer or your nearest Aftersales Service. Once

installed, packaging waste (plastic, styrofoam

parts etc.)

must be stored out of reach of

children - risk of suffocation. The appliance must

be disconnected from the power supply before

any installation operation - risk of electric shock.

During installation, make sure the appliance does

not damage the power cable - risk of fire or electric

shock. Only activate the appliance when the

installation has been completed.

WARNING : Modification of the appliance and

its method of installation are essential in order to

use the appliance safely and correctly in all the

additional countries.

Use pressure regulators suitable for the gas

pressure indicated in the instructions.

The room must be equipped with an air

extraction system that expels any combustion

fumes.

The room must also allow proper air circulation,

as air is needed for combustion to occur normally.

The flow of air must not be less than 2 m³/h per

kW of installed power.

The air circulation system may take air directly

from the outside by means of a pipe with an inner

cross section of at least 100 cm²; the opening must

not be susceptible to blockages.

The system can also provide the air needed for

combustion indirectly, i.e. from adjacent rooms

fitted with air circulation tubes as described above.

However, these rooms must not be communal

rooms, bedrooms or rooms that may present a fire

hazard.

Liquid petroleum gas sinks to the floor as it

is heavier than air. Therefore, rooms containing

LPG cylinders must also be equipped with vents

to allow gas to escape in the event of a leak.

This means LPG cylinders, whether partially or

completely full, must not be installed or stored

in rooms or storage areas that are below ground

level (cellars, etc.). It is advisable to keep only the

cylinder being used in the room, positioned so

that it is not subject to heat produced by external

sources (ovens, fireplaces, stoves, etc. ) which

could raise the temperature of the cylinder above

50

°

C.

Should you find it difficult to turn the knobs for the burner, please

contact the After-sales Service, who can replace of the burner tap if

found to be faulty.
The openings use for the ventilation and dispersion of heat must never

be covered.

Do not remove the appliance from its

polystyrene foam base until the time of

installation.

Connection with rigid pipe (copper or steel).

If the gas pressure is different from the

recommended pressure, a suitable pressure

regulator must be fitted to the inlet pipe in

accordance with the current National Regulations.

Donotinstalltheappliancebehindadecorative

door - risk of fire.

if the range is placed on a base, it must

be leveled and fixed to the wall by the

retention chain provided, to prevent the

appliance slipping from the base.
WARNING: In order to prevent the

appliance from tipping, the retention chain

must be installed. Refer to the instructions

for installation.

GAS CONNECTION

WARNING : Prior to installation, ensure that the

local distribution conditions (type of gas and gas

pressure) and the configuration of the appliance

are compatible.

Check that the pressure of the gas supply is

consistent with the values indicated in Table 1

(“Burner and nozzle specifications”).

WARNING : The configuration conditions of

this appliance are stated on the label (or data

plate).

WARNING : This appliance is not connected

to a combustion products evacuation device. It

Summary of Contents for IS5G1KMW/U

Page 1: ...IS5G1KMW U IS5G1KMW U IS5G1KMW U EN ENGLISH 2 Safety Instructions Installation Guide Daily Reference Guide 6 15...

Page 2: ...mental capabilities or lack of experience and knowledge can use this appliance only if they are supervised or have been given instructions on safe use and understand the hazards involved Children must...

Page 3: ...The room must be equipped with an air extraction system that expels any combustion fumes Theroommustalsoallowproperaircirculation as air is needed for combustion to occur normally The flow of air must...

Page 4: ...peration needs to be carried out by a qualified technician In order to adapt the appliance to a type of gas other than the type for which it was manufactured indicatedontheratinglabel followthededicat...

Page 5: ...vent negative consequences for the environment and human health The symbol on the product or on the accompanying documentation indicates that it should not be treated as domestic waste but must be tak...

Page 6: ...n H ob 6 Ignition button Control Knobs for G as Burners on H ob Thermostat knob Button for oven light 1 1 2 2 3 3 4 4 5 6 7 8 9 5 6 7 8 9 10 10 11 11 12 12 12 EN EN PRODUCT DESCRIPTION EN EN Read the...

Page 7: ...o different gas types On some models the gas supply can be connected on the left or on the right as necessary to change the connection reverse the position of the hose holder with that of the cap and...

Page 8: ...sistance Centres EN WARNING This operation must be perfomed by a qualified technician INSTALLATION TIPS INSTALLATION TIPS INSTALLATION TIPS INSTALLATION TIPS INSTALLATION TIPS INSTALLATION TIPS After...

Page 9: ...aptor or at the distribution board If you are in any doubt about the electrical supply to your machine consult a qualified electrician before use How to connect an alternative plug The wires in this m...

Page 10: ...e used They should also be suited to the size of the burner To identify the type of burner please refer to the diagrams contained in the Burner and nozzle specifications Using the oven The first time...

Page 11: ...g Oven light The light may be switched on at any moment by pressing the OVEN LIGHT button Timer To activate the Timer proceed as follows 1 Turn the TIMER knob in a clockwise direction for almost one c...

Page 12: ...Pizza Napolitan 1 0 4 210 220 15 20 25 Cake Biscuits Tarts Savoury pie Raised Cakes 0 5 1 1 1 0 1 0 4 4 4 4 180 180 180 170 15 15 15 15 25 35 40 45 50 55 40 45 Grill cooking Veal steaks Cutlets Hambu...

Page 13: ...a long time it s worth using a pressure cooker which is twice as fast and saves a third of the energy Respecting and conserving the environment Whenever possible avoid pre heating the oven and always...

Page 14: ...n it fully Lower the catches into their original position Make sure that you lower them down completely 5 Try closing the door and check to make sure that it lines up with the control panel If it does...

Page 15: ...15 17mm 0 67inch Min 420 mm Min 750 mm max 15 mm...

Page 16: ...EA S p A Via Carlo Pisacane n 1 20016 Pero MI Italy VAT number IT00693740425 16 10 2018 W11227768 10 2018 W11227768 10 2018 W11227768 Gas hose connection point must be installed within the shaded area...