GB
7
Table 1 Liquid Gas Natural Gas
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Rapid (R)
Semi Rapid (S)
Auxiliary (A)
Mini WOK (MW)
Supply pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
75
55
110
3.00
1.65
1.00
3.50
Nomin. Reduc.
0.70
0.40
0.40
1.50
By-pass
1/100
(mm)
39
28
28
61
Nozzle
1/100
Flow*
g/h
(mm)
***
86
64
50
91
Nozzle
1/100
Flow*
l/h
(mm)
286
157
95
333
218
120
73
254
**
214
118
71
250
Burner and nozzle specifications
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
3
116(Y)
96(Z)
79(6)
138
7,30 (531 g/h - G30) (521 g/h - G31)
IP 640 S UK
II2H3+
Gas section
Rated power (kW)
Class
Model
Electric section
220-240V~ 50/60Hz
Voltage and frequency
(1)
Power (W)
0,6
The values in g/h refer to the capacities with liquid gas (Butane, Propane).
(1)
IP 641 S C UK
II2H3+ 7,80 (567 g/h - G30) (557 g/h - G31) 220-240V~ 50/60Hz
0,6
A
S
R
S
IP 640 S UK
A
S
S
MW
IP 641 S C UK
Summary of Contents for IP 640 S (IX)