Indesit BIA series Service Quick Manual Download Page 2

Autotest: activation:

Activation:
1
 

Turn the fridge and freezer knobs to the minimum position (Off).

2 

Press the Super Freeze button for approximately 6 seconds.

Deactivation: 
1 

By switching the appliance on.

2 

By unplugging it.

3 

After 255 seconds of testing (end of autotest).

Artica Entry No Frost Fridge-Freezer Platform

2/2

Autotest Sequence:

 Step 

Duration 

Action 

Light  

Notese

 1 

seconds 

Pause 

OFF 

 

 

1 second 

Probe Check 

OFF 

If the probes have not failed, skip to step 3

 

 

 

 

 

If the probes have failed, skip to step 6

 3 

seconds 

Pause 

OFF 

 

 

125 seconds 

FZ Fan ON 

OFF

 

 

 

Resistenza ON (*)

  

 

Damper 

aperto 

 

 

120 seconds 

FZ Fan ON 

OFF 

Skip to step 8

 

 

 

Heating element ON (*)

  

 

Damper 

closed 

 

125 seconds 

FZ Fan ON 

Flashing

 

 

 

Heating element ON (*)

  

 

Damper 

closed 

 

 

120 seconds 

FZ Fan ON 

Flashing

 

 

 

Heating element ON (*)

  

 

Damper 

closed 

 8 

 

 

Autotest 

ends 

(*)  

Bear in mind that the heating elements are connected in parallel so, in the event only one of them 
is interrupted, the Fault will not be displayed

N. B.:   The Last Fault is cancelled at the end of the Autotest procedure

When Autotest is activated, any Last Fault or Non Critical Fault is shown on the display for the fi rst 
20 seconds, after which the Autotest sequence begins. In the absence of any fault, the sequence as 
described in the table begins. 