Autotest: activation:
Activation:
1
Turn the fridge and freezer knobs to the minimum position (Off).
2
Press the Super Freeze button for approximately 6 seconds.
Deactivation:
1
By switching the appliance on.
2
By unplugging it.
3
After 255 seconds of testing (end of autotest).
Artica Entry No Frost Fridge-Freezer Platform
2/2
Autotest Sequence:
Step
Duration
Action
Light
Notese
1
5
seconds
Pause
OFF
2
1 second
Probe Check
OFF
If the probes have not failed, skip to step 3
If the probes have failed, skip to step 6
3
4
seconds
Pause
OFF
4
125 seconds
FZ Fan ON
OFF
Resistenza ON (*)
Damper
aperto
5
120 seconds
FZ Fan ON
OFF
Skip to step 8
Heating element ON (*)
Damper
closed
6
125 seconds
FZ Fan ON
Flashing
Heating element ON (*)
Damper
closed
7
120 seconds
FZ Fan ON
Flashing
Heating element ON (*)
Damper
closed
8
Autotest
ends
(*)
Bear in mind that the heating elements are connected in parallel so, in the event only one of them
is interrupted, the Fault will not be displayed
N. B.: The Last Fault is cancelled at the end of the Autotest procedure
When Autotest is activated, any Last Fault or Non Critical Fault is shown on the display for the fi rst
20 seconds, after which the Autotest sequence begins. In the absence of any fault, the sequence as
described in the table begins.