background image

4

  For Metric Ballscrews the target value is 302.
  For Inch Ballscrews and Rotary tables the target value is 595.
Use the SETP command to check the current Ballscrew Type if you’re not sure about 
which ballscrew you may have.

The goal of the adjustment is to match the other axes so the system is dynamically 
balanced with all the XYZ axes.  It’s not required to be exactly set the value, it can be; +- 
10 counts, in most cases.  However it does somewhat affect the contouring accuracy; the 
closer the better.

7) Press the SLIDE HOLD key and adjust the 

Balance

 potentiometer of the amplifier to read 

a following error b1  and  - 1.

8) Press the START key and the program will start again. Verify that the following error is 

still correct starting from step 5 above.

9) Press the SLIDE HOLD key to stop the machine. Press the MANUAL key and then type 

SETCS and HO, to send the machine home.  Adjustment of the amplifier is complete.

Rotary Feedrate Selection Table

Note for Rotary Scales:

When disconnecting the rotary scale to adjust the amplifier, you must verify the SETP 
axis ratio has the correct mechanical ratio.  For example the TR65 B axis normally has 
the SETP set to a 180 to 1 ratio (when using the scale).  It must be temporally set to 90:1 
to adjust the amplifier without the scale feedback.  Using the SETP command, set the B 
axis ration back to 180 to 1 after adjusting the amplifier.  Changing the ratio requires 
cycling the power to the machine (off/on).

Publication No. D-9812-BRUSH AMP v1.5

February 2012

Reviews: