Isotemp Basic, Slim/B & Slim Square

                       Water heater 

 Installation and operating instructions

Indel Marine S.r.l.
Zona Artigianale sn
IT-61019 S. Agata Feltria (PU) Italy
Tel. +39 0541 848 030 

 

[email protected]

Fax +39 0541 848 563 

 

www.isotherm.com

Indel Marine USA Inc.
Gateway drive, Unit # 107
Pompano Beach, FL-33069
Phone: (954) 984-8448 

www.indelmarineusa.com

Fax: (954) 979-2533 

[email protected]

pantherRVproducts.com

Summary of Contents for 602421B000003

Page 1: ...l Zona Artigianale sn IT 61019 S Agata Feltria PU Italy Tel 39 0541 848 030 info isotherm com Fax 39 0541 848 563 www isotherm com Indel Marine USA Inc Gateway drive Unit 107 Pompano Beach FL 33069 Ph...

Page 2: ...4 2 Hoses 4 3 Connections to engine 4 4 Freshwater system connections 4 5 Electrical connections 5 Start up Test 6 Maintenance 6 1 Winterization 6 2 Replacing thermostat 6 3 Replacing heater element 7...

Page 3: ...o the power net until the water heater tank is filled with water Warning Risk of scalding the hot water in the water heater will be as hot as the engine Caution Consider the chapter 4 5 electrical con...

Page 4: ...The mounting brackets can be adjusted to the side on Basic and Slim for mounting the tank on a bulkhead Always mount the tank to a suitable shelf or bulkhead and keep in mind the extra weight of the t...

Page 5: ...OLD WATER IN Fresh warm water out Engine water in or out NPT outside thread Fresh cold water in FRESHWARM WATEROUT 514 NPT outside thread NPT outside thread ENGINE MOTOR WATER ENGINE MOTOR WATER FRESH...

Page 6: ...ater in ENGINE MOTOR WATER FRESH COLD WATER IN ENGINE MOTOR WATER Second heat exchanger in or out NPT outside thread ENGINE MOTOR WATER ENGINE MOTOR WATER WARM WATER OUT NPT outside thread FRESH WARM...

Page 7: ...ot water spray 4 2 Hoses For the engine connections use heat re Fig 7 sistant 100 C 210 F reinforced rubber hoses resist ant to anti freeze and pressure approved for 5 bar 70 psi For the fresh water c...

Page 8: ...s have a free outlet A small quantity of water can drain from the relief valve when the tank is heated The water expands during heating This is a normal situation and indicates the system works proper...

Page 9: ...hoses and blowing air into the coils to drain any water The tank can now be safely left in the vessel over the winter When leaving the vessel for longer periods it is recommended to take out the powe...

Page 10: ...from the mounting flange Mount the new heating element with new seal rings and a new big rubber gasket in the opposite order to the description above The inner end of the heating element shall point s...

Page 11: ...V 1200W X 605021B000003 13 50 7 115V 750W 230V 750W 230V 1200W 230V 2000W X 607521B000003 20 64 115V 750W 230V 750W 230V 1200W 230V 2000W 230V 3000W X 607523BD00003 Double heat exch 20 68 4 115V 750W...

Page 12: ...115V 750W 230V 750W X 602521S000003 6 5 30 115V 750W 230V 750W X Dimensions See fig 13 Material Heat exchanger coil storage tank and connections stainless steel AISI 316 Outside cover and mouting brac...

Page 13: ...03 4 2 35 115V 750W 230V 750W X Dimensions See fig 14 Material Heat exchanger coil storage tank and connections stainless steel AISI 316 Outside cover and mouting brackets Stainless steel AISI 304 Out...