![Indel B TB 20 BT Instructions For Use Manual Download Page 20](http://html1.mh-extra.com/html/indel-b/tb-20-bt/tb-20-bt_instructions-for-use-manual_2051409020.webp)
18
TB 20 BT
TB20BT_(DC)_IM_20190716
MAINTENANCE
Before carrying out any maintenance operation on the refrigerator, take the power cable out of its
socket.
CLEANING
• Regularly clean the inside and outside of the refrigerator using only warm water and a neutral detergent.
• After washing, rinse with clean water and dry thoroughly using a soft cloth.
• Do not use the following: special glass and mirror cleaning products, liquid, powder, or spray detergents,
alcohol, ammonia or abrasive products.
• When the refrigerator is not being used, it is advisable to clean the inside thoroughly and leave the door
half open to ventilate the interior.
SUGGESTIONS
If the device fails to operate or malfunctions, before contacting the support service, ensure that:
a) the feeding voltage is not missing;
b) the voltage is the same as the one shown on the plate;
c) the connections and the polarities are right;
d) the airing grids are not covered over;
e) the refrigerator unit is not near any heat source;
f) the fuse of the feeding line is not blown.
The power supply cable must only be replaced by a qualified technician and in any case by an aftersales
service authorised by the manufacturer.
Indel B is not liable in any way if you do not comply strictly with all the previsions in this manual.
FAULTS
When there is error for the fridge, there will be code on the display. The possible error for each code would
be as follows
ERROR
CODE
ERROR TYPE
E1
Battery protection
(The voltage is outside the cut-out setting).
E2
Fan over-current cut-out
(The fan loads the electronic unit with more than 1A
peak
).
E3
Motor start error
(The rotor is blocked or the differential pressure in the refrigeration system is too high (>5 bar)).
E4
Minimum motor speed error
(If the refrigeration system is too heavily loaded, the motor cannot maintain minimum speed
1,850 rpm).
E5
Thermal cut-out of electronic unit
(If the refrigeration system has been too heavily loaded, or if the ambient temperature is high, the
electronic unit will run too hot).
E6
NTC temperature probe failure
(NTC open circuit or short circuit)