Inalto II64T User Manual Download Page 4

USER MANUAL

PAGE 06

PAGE 07

SPECIFICATIONS

       

MODEL

PRODUCT DIMENSIONS (W×D×H) 

CUT-OUT DIMENSIONS (W×D)

II64T

590mm, 520mm, 56mm

560mm x 490mm

MODEL

BURNERS

OTHER

II64T

x 1.85/2.10 kW induction zones 

(Ø 200mm) 

2 x 1.40 kW induction zones 

(Ø 160mm)

Touch control operation

Automatic pot/pan detection

4 individual residual heat indicators

Frameless

 

INDUCTION COOKTOP SURFACE LAYOUT 

 

A  1.85 / 2.10 kW zones (Ø 200mm)
B  1.40 kW zone (Ø 160mm)

It’s important to carefully read the following installation instructions before beginning the installation of your cooktop.

IMPORTANT!

  

The connection of this cooktop must be carried out by a suitably qualified and licensed person, in 
accordance with the current version of the following:

►   AS/NZS 3000: 2007 Wiring Regulations
►  2010 Electricity Safety Regulations
►   The installation instructions within this user manual

POSITIONING

Warning. The adjacent furniture must be able to withstand a minimum temperature rise of 85°C above the ambient 
temperature of the room it is located in, during periods of use.

This cooktop is to be built into a kitchen unit (depending on size) or 600mm cooktop that is at least 30mm thick. The 
following minimum clearance distances must be observed:

►  700mm between the cooktop surface and the underside of any horizontal surface above it.
►   50mm clearance around the front and sides of the appliance, and 55mm clearance at the back of the appliance, 

measured from the cut out, providing the material next to the cooktop is made of a non-combustible material.

►   If the cooktop is positioned so that the right or left hand side of the appliance will be near to the edge of a kitchen unit. 

There must be a gap of at least 150mm between the side of the cooktop and the vertical surface of the kitchen unit.

IMPORTANT!

 

 Underneath the appliance there MUST be a partition made of insulating material (e.g. wood). There 
must be a gap of at least 20 mm between the underneath of the appliance and this partition.

▷  You must make sure that there is a 5mm gap below the underneath of the worktop at the front edge of the hob.

IMPORTANT!

 

 If you are installing this cooktop above an oven the oven MUST have a cooling fan.

INSTALLING THE COOKTOP 

►  Cut a hole in the bench top that corresponds with the relevant drawing on page 6.

YOUR INALTO COOKTOP

INSTALLATION INSTRUCTIONS

TOUCH CONTROLS

A

B

B

A

590

520

56

Min.

 6

5

Summary of Contents for II64T

Page 1: ...MODEL CODE S II64T PRODUCT INDUCTION COOKTOP DOCUMENT USER MANUAL...

Page 2: ...he most out of your appliance Should you want to learn more about recommended cooking temperatures the various cooking functions available and importantly taking care of your appliance when cleaning o...

Page 3: ...hould not allow the electrical connection cables to come into contact with the cooktop surface when it is hot or any hot cookware If fat and oil overheats then it can ignite extremely quickly For this...

Page 4: ...nit depending on size or 600mm cooktop that is at least 30mm thick The following minimum clearance distances must be observed 700mm between the cooktop surface and the underside of any horizontal surf...

Page 5: ...must NOT be connected to the mains supply by means of a 13A plug and socket The cable connections must be in accordance with the diagram located on the bottom of the cooktop The links must also be pos...

Page 6: ...used The child lock will become active again after switching off the zones To cancel the child lock Simultaneously press a cooking zone selection button 4 and the Decrease button 3 and the press the...

Page 7: ...imer will be cancelled OPERATING YOUR COOKTOP OPERATING YOUR COOKTOP COOKWARE THAT IS SUITABLE FOR AN INDUCTION COOKTOP The table below shows cookware that is normally suitable for use on an induction...

Page 8: ...TROUBLESHOOTING Some minor faults can be fixed by referring to the instructions given below There is also a self help section online at http www residentiagroup com au The cooking zones are not funct...

Page 9: ...nection 32A double pole switch fuse outlet with 3mm contact gap Max Rated Inputs 7 0kW Mains Supply Lead 5 core x 1 5mm not supplied TECHNICAL DATA ERROR MESSAGES The following tables outline error co...

Page 10: ...ii misuse or abuse including failure to properly maintain or service iii normal wear and tear iv power surges electrical storm damage or incorrect power supply v incomplete or improper installation v...

Page 11: ...MODEL CODE S II64T...

Reviews: