background image

M O D E L   C O D E

I C G 9 0 5 W

90cm 

Gas Cooktop

U S E R   M A N U A L

I N A LT O . H O U S E

A   H I G H E R   L E V E L   O F   C O O K I N G

V. 4   |   0 9 2 0

Summary of Contents for ICG905W

Page 1: ...M O D E L C O D E I C G 9 0 5 W 90cm Gas Cooktop U S E R M A N U A L I N A LT O H O U S E A H I G H E R L E V E L O F C O O K I N G V 4 0 9 2 0...

Page 2: ...up www applico co nz www inalto house Both Residentia Group Applico are customer obsessed and our Support Teams are there to ensure you get the most out of your appliance Should you want to learn more...

Page 3: ...ooktop 9 Burners 10 Cleaning and Care 11 Troubleshooting 12 Technical Data 13 Installation Instructions 14 Installation Procedure 16 Gas Connection 20 LPG Conversion 21 Electrical Connection 22 Testin...

Page 4: ...damage or marks If you find the appliance is damaged or marked you must report it within 7 days if you wish to claim for damage marks under the manufacturer s warranty This does not affect your statut...

Page 5: ...by a person responsible for their safety Children should be supervised to ensure they do not play with this appliance During use this appliance becomes hot Care should be taken to avoid touching hot...

Page 6: ...NER Stainless Steel Hob Cast Iron Trivets 3 Rapid Burner Auxiliary Burner Semi Rapid Burner 2 Burner Control Knobs Glass Panel beneath the Burner Control Knobs Burner Flame Ports Ignition Spark Plug F...

Page 7: ...e person If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard WARNING Never install a cooktop that has been...

Page 8: ...s only To light a burner the knob must be turned to the then pushed down as far as possible for approximately 5 seconds If the flame goes out when the knob is released simply depress the knob again th...

Page 9: ...t or pan To conserve gas place the pan centrally over the burner and adjust the flame so that it does not extend past the edge of the pan Figure 4 Do not boil food too rapidly A vigorous boil will not...

Page 10: ...However it must be remembered that as it is GLASS it may break Treat it accordingly To clean the glass panel use a soft cloth or sponge with detergent and warm water TRIVETS AND BURNERS These can all...

Page 11: ...disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty Dry or clean ignition spark plugs Flames uneven or tending to lift Flame ports blocked or wet Clean...

Page 12: ...st Hob Material Stainless Steel Features Ignition under knob Flame Failure Safety Yes Colours Stainless Steel Gas Types NG LP conversion kit supplied COOKTOP PHYSICAL DIMENSIONS mm Width 860 Depth 510...

Page 13: ...ng regulations and any other relevant statutory regulations The particular instructions as given below A certificate of compliance MUST be given to the customer after the application is successfully i...

Page 14: ...ve an underbench oven or similar appliance and or if the cupboard construction is such that the underside of the cooktop is not accessible Ensure that there is an earthed power outlet within 900mm of...

Page 15: ...it into the aperture hole that you have cut out in your benchtop On the underside of the hob adjust the brackets into a position that is suitable for your benchtop Then fully tighten the screws C to...

Page 16: ...250mm The point of connection to consumer piping must be accessible with appliance installed ELBOW POSITIONING It is possible to reposition the elbow if required by loosening the locking nut and elbo...

Page 17: ...C 3 Invert the adapter within the top cover as per Figure 7D 4 Reinsert the top cover into the Regulator NOTE Do not adjust the regulator valve body piece in the above procedure as it will affect the...

Page 18: ...the inlet and outlet of the regulator is orientated correctly When the regulator has been fitted check for leaks from the connections with soapy water Figure 8A Figure 8B The tapered thread connects...

Page 19: ...re may be too low and adjustment of an upstream regulator may be needed or an upstream regulator or valve with insufficient flow capacity may be present in the gas supply line If this is suspected the...

Page 20: ...ing check the outlet pressure when all burners of the appliance are operating at maximum when the smallest burner of the appliance is operating at minimum Under these conditions the outlet pressure sh...

Page 21: ...egulations Diagram 1 is a schematic of the wiring in the appliance Diagram 1 ICG905W IMPORTANT This appliance must be earthed This appliance is designed to be connected to a 220 240V 50Hz 60Hz AC elec...

Page 22: ...ANT If the appliance has been converted to LPG then the bypass screw will HAVE to be screwed in until a small stable flame results Please ensure the supply pressure has been checked PRIOR to any adjus...

Page 23: ...23 Figure 9 Figure 10 Flame size adjusted to maximum Flame size adjusted to minimum Bypass screw...

Page 24: ...e please record the following information which can be found on the rating plate and the date of purchase which can be found on your sales invoice STORE DETAILS STORE NAME ADDRESS TELEPHONE PURCHASE D...

Page 25: ...ccident negligence alteration misuse or incorrect installations f a product dismantled repaired or serviced by any serviceman other than an authorised service agent g a product not in possession of th...

Page 26: ...e sale and your has a corresponding meaning 2 This warranty only applies to Appliances purchased and used in Australia and is in addition to and does not exclude restrict or modify in any way any non...

Page 27: ...jor failure The benefits to you given by this warranty are in addition to your other rights and remedies under a law in relation to the Appliances or services to which the warranty relates 11 At all t...

Page 28: ...A H I G H E R L E V E L O F C O O K I N G W W W I N A LT O H O U S E...

Reviews: