Inakustik AC-2404 AIR Operation Manual Download Page 3

OPERATION MANUAL

PREMIUM USB CAR POWER ADAPTER QC 5/9/12V

in-akustik GmbH & Co. KG
Untematten 12-14
79282 Ballrechten-Dottingen
GERMANY

Tel.:       +49 (0) 7634 5610-70
Fax.:      +49 (0) 7634 5610-80
E-Mail:  [email protected]
Web:     www.in-akustik.com

r

MADE IN 
GERMANY

OPERATION MANUAL

AC-2404 AIR 

ITEM-NO.: 0076260XX | 0076261XX | 0076262XX | 0076263XX | 0076264XX | 0076265XX

GENERAL

Read, observe and adhere to the following safety instructions. Please keep the operating manual. Observe all the warning notices on the components and in the operating manual.

PROPER USE

• 

This power cord may only be used for the connection of stationary HiFi and High-End consumer electronics devices that do not develop heat.

• 

This power cord must only be used in dry areas.

• 

Please also note the operating instructions of the devices you would like to connect.

General

• 

All cables must be positioned in such a way that there is no danger of them being damaged (e.g. being stepped on, placed under furniture, fall of objects etc.). 

• 

Never kink, squeeze, pull over sharp edges or stress the power cord otherwise.  

• 

Make sure that no foreign objects or liquids enter the components.

• 

Keep children and pets away. Spittle and bites can damage the insulation and may cause lethal electric shocks!

• 

Never remove cables by pulling the cable; instead, always hold the plug when disconnecting.

• 

Do not under any circumstances expose the components to high levels of humidity. Extreme temperature fluctuations, humidity and extended exposure to light can damage the components and alter their 

appearance

Humidity

Select an installation location for the components which does not have a high level of relative humidity and is free of moisture. Never use the components near water. Moisture can bypass the electrical insulation 
and pose a lethal danger, as it can for all products not specially designed to be water-resistant. The components may not be exposed to dripping or sprayed water.

Positioning

Do not position the components near sources of heat, heaters, heating valves, ovens or other heat-producing devices. The components may only be stored and operated in the temperature range stated. The 
components heat up during operation.

Connection

The power cord must only be connected to the maximal rated voltage! Check the power cord for possible damage before connecting. Never use a damaged power cord! This must be repaired by a specialist or 
disposed of! In stand-by mode, the components are not completely disconnected from the mains supply. To avoid any unnecessary hazards or energy consumption during longer absences, the components should 
be disconnected from the mains supply.

Maintenance

Maintenance on the product may only be performed by persons qualified to do so. Maintenance is necessary in all cases of damage, i.e. in the case of damaged cables and plugs, as well as after liquid spills or 
objects falling on the components, components falling down, foreign bodies entering the components, exposure of components to rain or humidity, or other influences impairing the functioning of the components.

Looking after the product

Disconnect the components from the power supply before cleaning them Always clean the components with a soft, dry and lint-free cloth, or with a brush. Do not under any circumstances use scouring powder, 
alcohol, benzine, furniture polish or similar substances.

USAGE OF POWER DISTRIBUTOR BARS

When using multiple power boards and extension cables, pay special attention to the DIN VDE 0100 part 420, para. 4.1 (risk of fire in electrical installations). Furthermore, the VDE 0100-410:2007-06 also 
requires short breaks of 0.4 s for the TN system. The temperature of the cable may rise in such cases to the point of causing a fire. Therefore, the following applies to ALL power boards: Do not connect them in a 

row and do not use if covered!

DESCRIPTION

Thank you for using this product.
Extreme current peaks are the greatest challenge for mains connection cables. They are caused by transforming alternating current into direct current in the connected devices. The reason for this is that the char-
ging capacitors of the devices can only charge in the brief time in which the voltage at the apex of the mains AC voltage is higher than that of the capacitors themselves. This leaves current peaks that are almost 
needle-like that are several times higher than the rated current of the devices. Because the capacitors discharge again by the next apex, this process is repeated 100 times per second or even 120 times per second 
with a 60 Hz mains frequency.

The extreme current peaks have a whole range of undesired effects: 

On the one hand, they cause noticeable voltage and therefore power losses at cable and contact resistances. On the other hand, they create strong magnetic fields that cause appreciable skin effects even at relati

-

SAFETY INSTRUCTIONS

• 

Check for damage before use!

• 

Do not use with recognizable or suspected damage!

• 

Use for stationary operated devices only!

• 

Use for devices that do not develop heat only!

• 

Use inside dry rooms only!

• 

Never pull the cable!

• 

Connect and disconnect by holding the plug only!

• 

Protect from humidity and wetness!

• 

Protect from heat and direct sunlight! 

• 

Keep away from small children and pets!

• 

Do not kink, squeeze or otherwise strain!

• 

Do not pull over sharp corners or edges!

• 

Do not cover.

• 

Do not open, repair yourself!

• 

Do not modify!

Reviews: