IMV BUG-OLED Instruction Manual Download Page 6

www.imv-imaging.com  |  7

6  |  

1.2 Display positioning

The displays are designed to allow 
you to see the ultrasound image 
in front of your eyes. This ensures 
maximum animal awareness 
whilst ensuring a clear view of the 
image.

Fig 1.

 Too close: head gear is 

hitting the forehead causing 
discomfort and limiting adjustment.

Fig 2.

 Too far: Distance from eyes 

is too great causing a less than 
optimal image.

Fig 3.

 Correct fit (flexi headband 

only): To test if the housing is too 
close, place BUG on your head 
and press unit into your forehead. 
If the unit is in the correct position, 
you should only just be able 
to press the housing onto your 
forehead. 

Fig 4.

 Correct fit (firm  

headband only): To set the 
goggles as close as possible to 
your eyes without the housing 
touching your forehead, adjust  
the inner headband angle 
(position on your forehead) and 
then pivot the outer band for 
correct display alignment.

Fig 5.

 Raised position (for both 

headbands): You can move 
goggles up and down as you 
would do with sunglasses when 
not in use. This positioning is useful 
when you are not scanning.

If glasses are normally worn then 
please continue to use glasses. This 
position will not be affected by 
glasses. 

STRAP ADJUSTMENTS

1

2

STRAP ADJUSTMENTS

1

2

TOO FAR

CORRECT FIT

STRAP ADJUSTMENTS

inner headband

version 1 raised

 

STRAP ADJUSTMENTS

1

2

STRAP ADJUSTMENTS

1

2

TOO FAR

CORRECT FIT

STRAP ADJUSTMENTS

inner headband

version 1 raised

 

Fig 1.

 Too close

Fig 2.

 Too far

STRAP ADJUSTMENTS

1

2

STRAP ADJUSTMENTS

1

2

TOO FAR

CORRECT FIT

STRAP ADJUSTMENTS

inner headband

version 1 raised

 

STRAP ADJUSTMENTS

1

2

STRAP ADJUSTMENTS

1

2

TOO FAR

CORRECT FIT

STRAP ADJUSTMENTS

inner headband

version 1 raised

 

Fig 3.

 Correct fit  

(flexi headband)

Fig 4.

 Correct fit 

(firm headband)

STRAP ADJUSTMENTS

1

2

STRAP ADJUSTMENTS

1

2

TOO FAR

CORRECT FIT

STRAP ADJUSTMENTS

inner headband

version 1 raised

 

Fig 5.

 Raised position

1. Operating instructions

Summary of Contents for BUG-OLED

Page 1: ...Instruction manual Your complete animal imaging solution ...

Page 2: ...2 BUG versions ...

Page 3: ...nnecting to scanner 1 2 Display positioning 1 3 Strap adjustment firm headband 1 4 Brightness adjustment 2 Care and maintenance 2 1 Care 2 2 BUG facts 2 3 Maintenance 3 Technical specifications 3 1 BUG specifications 3 2 VGA BUG specifications 4 Service centres 4 5 5 6 7 7 7 8 8 8 8 9 9 10 11 ...

Page 4: ... 3NJ Scotland UK 44 0 1506 460 023 info imv imaging com www imv imaging co uk As specialists in providing ultrasound imaging equipment for animal husbandry applications we understand the importance of using reliable equipment All IMV imaging products are designed and manufactured to withstand the environments in which they are used However should you experience any problems with your BUG IMV imagi...

Page 5: ...ut a break Mounting the glasses above the line of sight as recommended in this manual will assist your comfort Operator safety 1 Operating instructions 1 1 Connecting to scanner BUG goggles are available with two different types of connectors One is screw type and the other is a push fit With the screw type the connector must be screwed tight into the scanner to ensure environmental proofing of th...

Page 6: ... for correct display alignment Fig 5 Raised position for both headbands You can move goggles up and down as you would do with sunglasses when not in use This positioning is useful when you are not scanning If glasses are normally worn then please continue to use glasses This position will not be affected by glasses STRAP ADJUSTMENTS 1 2 STRAP ADJUSTMENTS 1 2 TOO FAR CORRECT FIT STRAP ADJUSTMENTS i...

Page 7: ...s please visit the Service and support section on our website www imv imaging com Fig 6 Strap adjustment firm headband 1 2 1 4 Brightness adjustment When the BUG devices are connected to the newest model of Easi Scan the brightness of the image can be adjusted from the scanner s setup menu Refer to the Easi Scan user manual for details This feature is not available when used with Duo Scan or older...

Page 8: ... not withstand powerful water jets i e tap full on hose down or immersion in water BUG devices are available with two different connector types The push fit connector is sealed to IP65 and is splash resistant to the same level as the housing The screw connector is only sealed when properly secured to the scanner but is vulnerable when disconnected Do not rinse or submerge the connector 2 3 Mainten...

Page 9: ... 850 cd m2 white Contrast ratio 300 1 Headset Power consumption 700 mW 5 V Easi Scan 3 or 900 mW 6 5 V Easi Scan 3 or Duo Scan Voltage input 5 0 V to 6 5 V Environmental proofing IP65 Video format NTSC PAL monochrome auto detect Temperature range 40 C to 40 C 40 F to 131 F Weight 300 g Compatible with Easi Scan and Duo Scan 3 Technical specifications ...

Page 10: ...display per eye Pixel resolution VGA 640 x 480 Display size 9 x 6 8 mm Luminance 160 cd m2 white Contrast ratio 80 1 Headset Power consumption 1 2 W Voltage input 4 8 V to 10 V Environmental proofing IP65 Video format NTSC PAL Monochrome Auto detect Temperature range 10 C to 40 C 14 F to 104 F Weight 235 g Compatible with Easi Scan Possible to connect to Duo Scan older versions of Easi Scan with a...

Page 11: ...0 42 932 0070 ireland imv imaging com www imv imaging ie United Kingdom HQ IMV imaging Imaging House Phoenix Crescent Strathclyde Business Park Bellshill ML4 3NJ Scotland UK 44 0 1506 460 023 info imv imaging com www imv imaging co uk France IMV imaging 126 Boulevard de la République 16000 Angoulême France 33 4 3702 1766 france imv imaging com www imv imaging fr North America IMV imaging 2900 43rd...

Page 12: ...facebook com IMVimaging twitter IMVimaging www imv imaging com info imv imaging com 44 0 1506 460023 Contact us now Your complete animal imaging solution ...

Reviews: