background image

 
 

  3 

 

VP-420/421 Specifications Rev5.0 

 

Introduction

 

Thank you for purchasing

 

Direct Output Vibration Pickup “VP-420” or “VP-421”. 

Read this instruction manuals carefully to ensure the best performance and longest product 

life of the device. In addition, pay attention to the cautions described below to use the 
product safety. 

 

Caution 
(1) Direct Output Vibration Pickup (hereinafter referred to as "pickup") is a device that 

diagnoses various vibration for industrial equipment such as electric motors and pumps, 
and consumer equipment. Do not use it for any other purpose. 

(2) When wiring pickup, make sure that power supply source is "off" before performing the work. 
(3) Signal line from pickup should not be bundled with the power line or the signal line that 

generates noise but should be laid in a separate system. 

 

Safety Precautions 

It describes the items that you should follow in order to prevent harm to customers and 

other people and damage to property, and to use this product safely. Please be sure to read 
this instruction manuals and attached documents before use, and fully understand the 
contents for use. 

After reading this manual, be sure to place it in a location so that you can always refer to it. 

 

Expressions of Safety Instructions 

Indication 

Meaning of Indication 

   

Warning

 

Indicates the contents that may cause a dangerous situation of death 
or serious injury if mishandled. 

   

Caution

 

Indicates the contents that may cause serious injury or property 
damage if mishandled. 

Note

 

Describes cases where there is no risk of injury to the operator, but it 
is expected to cause damage or failure to this product or other 
equipment or devices. 

* "Serious injuries" are those with residual aftereffects such as blindness, injury, burns, electric shock, 

fractures, poisoning etc., and those requiring hospitalization or long-term hospital visits for treatment. 

* "Minor injuries" are those that do not require hospitalization or long-term hospital visits for treatment 

(other than the "serious injuries" above). 

 

In addition to the danger level classification, this document also uses the following notation: 

Memo: "Memo" describes supplementary explanations that could not be explained in the 

text and information that is useful to know. 

 

 

Summary of Contents for 4P-420

Page 1: ...nstruction Manuals Direct Output Vibration Pickup Model VP 420 4 20mA Velocity Type VP 421 4 20mA Velocity AC Acceleration Type Manufacturer IMV CORPORATION Specification No VP 420 TVE 5 5676E VP 421...

Page 2: ...sions 7 4 Outer Dimensions of Mounting Adapter Quick Fit 8 5 Frequency Response 8 6 Outline View of Connector Cable 9 7 Instructions 10 7 1 Installation of Pickup 10 7 2 Laying of Pickup Cable 10 7 3...

Page 3: ...is instruction manuals and attached documents before use and fully understand the contents for use After reading this manual be sure to place it in a location so that you can always refer to it Expres...

Page 4: ...zed do not touch the terminal block etc carelessly Note 1 When wiring pickup check the method that matches the specifications of the device to be connected Improper connection may cause the product or...

Page 5: ...rements based on ISO10816 which defines the vibration severity is possible by this product 2 Output is 4 20mA DC which is proportional to the vibration level 3 This product has the capability of inter...

Page 6: ...ax at 24VDC Dimensions Detail Reference 3 Outer Dimensions Drip proof Direct connect Type 27 5 45mm Excluding Protrusions Water proof Connector Type 27 5 56mm Excluding Protrusions Water Resistant Typ...

Page 7: ...27 5 HEX 28 56 66 5 W5 8 Depth 6 Sensor Body VP 420 Pin Assign Pin1 NC Pin2 15 to 30VDC White Pin3 NC Pin4 0V Black 27 5 HEX 28 69 44 5 2 W5 8 Depth 6 Sensor Body VP 420 Cable White 15 to 30VDC Black...

Page 8: ...Mounting Adapter Quick Fit MS AS001 for Glue Face MS AS002 M8 Male MS AS003 M6 Male MS AM005 Magnet 25 4mm Pole Piece Unit is mm 5 Frequency Response 24 W5 8 5 5 3 5 6 24 8 5 3 5 W5 8 M8 6 24 8 5 3 5...

Page 9: ...heath Material PUR Cable Outer Diameter 5 9 Standard Outline View See below Figure Brown White Silver Shield Blue No use Black MS AC010 Straight Connector MS AC011 Angle Connector 15 15 28 46 46 Brown...

Page 10: ...ickup mounting surface cleanly finished Completely remove dirt dust paint etc Also make sure that the tapped holes are upright with no foreign matter on the threads 7 2 Laying of Pickup Cable 1 Pickup...

Page 11: ...eceiver such as logger with 1 5V connect 250 resistance with it in parallel Fig 7 2 is just an example of wiring For details on connecting pickup to the receiver Logger PLC DCS etc refer to the instru...

Page 12: ...with it in parallel Fig 7 3 is just an example of wiring For details on connecting pickup to the receiver Logger PLC DCS etc refer to the instruction manual of the receiver Also check the instruction...

Page 13: ...pose of it as industrial waste 9 Warranty If this product has the fault caused by the responsibility of IMV as the defect under production and material during warranty period we will repair or replace...

Reviews: