Installation Instructions (Surface-Mount)

1.  Position mounting base in desired location and secure using 

(3) #4 flat head screws.

2.  Twist and remove the trim ring from 

the LED subassembly. Connect the 

LED subassembly to a DC power 

source by passing the wires through 

the mounting base following the 

wiring instructions in the next section 

of this guide. 

3.  Once all electrical connections are 

made, place the LED subassembly 

housing into the mounting base, 

line up the holes, and secure with 

(3) machine screws (included).  (see 

Figure 4).

4.  Place the trim ring over the light 

making sure the tabs of the trim ring 

engage with the openings in the  

housing. Twist the trim ring on to 

secure it.

Figure 4

WIRING INSTRUCTIONS

Sigma may be controlled by either basic on/off or by a remote 

dimmer.  Both the power (on/off) and dimming function is 

achieved with the two lead wires provided. 
1.  Connect the light to a DC (or low voltage AC*) power source. 

Connect the red wire to positive DC voltage and the black 

wire to negative or ground. 

*Note: Magnetic transformers only 

2.  Dimmer compatibility: If you are replacing halogen or 

incandescent fixtures that use a remote DC dimmer, your new 

lights will use the same power/control wires but may or may 

not be compatible with the existing dimmer. If after testing 

your lights with the existing DC dimmer you are not satisfied 

with the performance, then we recommend the use of Imtra’s 

Intervolt DC Dimmer which these lights have been optimized 

for. Please contact Imtra or visit our website for details on this 

dimmer. 

3.  Transformer compatibility: Sigma is designed to work with 

10-40VDC as well as low voltage AC (from a magnetic 

transformer) but on non-dimming circuits only. Electronic 

transformers are not compatible. If dimming is required, then 

the transformers may be replaced with LED converters sized 

appropriately. Please contact Imtra for assistance. 

Wire

Function

Red

+ Dim/Power

Black

– Dim/Power

NOTES ON WIRE SIZE

The PowerLED family of products comes equipped with 

integrated driver electronics.  These components are sensitive 

to DC systems with voltage drops.  Therefore, it is imperative to 

select the correct wire size to supply DC voltage to the lights.  

This prevents excessive impedance and voltage drops which can 

cause premature failure in the PowerLEDs.  It is recommended 

that the supply wire size be selected according to the ABYC 

Wiring Recommendations Chart for a 10% voltage drop.  These 

charts can be found at www.imtra.com. 

Wiring Diagram

No Dimming

• 

Single Switch Location

• 

Sigma

PowerLED

Voltage Supply

(battery, transformer, 

converter, etc)

1-Way Switch

1P/1T - On/Off

Sigma

PowerLED

Reviews: