3.2 Explosion proof model
The explosion proof model light fitting has a type plate attached:
This contains the following information:
1.
Type
: Low temperature range
IQL55-FL-LT
IQL85-FL-LT
IQL165-FL-LT
: Normal temperature range
IQL55-FL
IQL85-FL
IQL165-FL
2.
Ambient temp.
: Low temperature range
-40°C up to 40°C
: Normal temperature range
-20°C up to 40°C
3.
Serial number
4.
Year of Manufacture
5.
Frequency
: AC 50/60
: DC none
6.
Voltage
: 200-277Vac/dc or 100-120Vac/dc
7.
Current
:
100-120 Vac/dc
200-277 Vac/dc
: 55W 460mA
260mA
: 85W 730mA
400mA
:165W 1420mA
740mA
8.
Labeling
: 55W FL
II 2 GD Ex e mb II T4 T135°C
: 85W FL
II 2 GD Ex e mb II T4 T135°C
: 165W FL
II 2 GD Ex e mb II T3 T160°C
9.
Ingress Protection
: IP66