Complete Home

Water Leak Detection Alarm

Installation Instructions

Imrita

Summary of Contents for IMT-P-ZL6

Page 1: ...Complete Home Water Leak Detection Alarm Installation Instructions Imrita ...

Page 2: ...ion The main alarm unit houses the valve flow meters and electronics for setting up the system It is housed in a waterproof case to protect the electronics and offer a long service life All the settings are made either via the main alarm unit or by using the E Water app MainAlarm Unit Menu Button Press and hold for 5 seconds to enter the settings mode Open Button This will open the valve if closed...

Page 3: ...itted before and after the unit to assist should it need to be removed Installing the main alarm unit 127 5mm 230mm 3 4 BSP 3 4 BSP 96 5mm Note Width 85mm ENVIROTECH ALARMS IMRITA INSTALLATION INSTRUCTIONS VERSION 1 0 Installing the Battery Backup On the bottom of the main unit remove the lower of the two battery compartment covers Carefully extract the battery connection cable Connect the battery...

Page 4: ...n for 5 seconds This enters the setting mode The minute digits will start to flash Use the CLOSE button to increment the numbers to the correct time MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press the MENU button again to enter time setting MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press and hold the MENU b...

Page 5: ...he OPEN button to toggle to the 10s of litres setting This will start to flash MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press and hold the MENU button for 5 seconds This enters the setting mode The L on the right will illuminate and the digit on the right will start to flash Press the CLOSE button to increment the amount up...

Page 6: ...x Flow L min L min MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press and hold the MENU button for 5 seconds This enters the setting mode The min on the right will illuminate and the digit on the right will start to flash Press the CLOSE button to increment the amount up in minutes MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press the MENU button again three times to en...

Page 7: ... for 5 seconds This enters the setting mode The min on the right and the Leak Time on the left will illuminate and the digit on the right will start to flash Press the CLOSE button to increment the amount up in minutes MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press the MENU button again four times to enter water time setting Note If still in the setting mode press the MENU button ...

Page 8: ...still in the setting mode press the MENU button once to enter the max flow setting MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Use the CLOSE button to increment the numbers to the desired threshold level Press the OPEN button again to toggle to the 100s of litres setting This will start to flash MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press and hold the MENU button ...

Page 9: ... to increment the amount up in seconds MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press the MENU button again six times to enter auto restore setting Note If still in the setting mode press the MENU button once to enter the auto restore setting MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press and hold the MENU button for 3 seconds to store water time settings Note I...

Page 10: ...t the amount up in days MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press the MENU button again seven times to enter auto auto valve setting Note If still in the setting mode press the MENU button once to enter the auto valve setting MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press and hold the MENU button for 3 seconds to store water time settings Note In the exampl...

Page 11: ...o increment the amount up in days MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press the MENU button again eight times to enter auto valve test setting Note If still in the setting mode press the MENU button once to enter the valve test setting MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press and hold the MENU button for 3 seconds to store water time settings Note In ...

Page 12: ... floor accessed by removing the bath panel Another could be positioned behind the sink WC area although care should be given to the possibility that water used for cleaning could contact the sensor and trigger an alarm Ideally this sensor should be placed on the floor inside any pipework boxing with a panel left to gain access in the event of a leak Position 3 Utility Rooms Like with the kitchen t...

Page 13: ... x 5 Place the remote sensor probe in a small amount of water The main unit will beep twice and the red light on the sensor will start to flash OPEN CLOSE MENU Volume Time Leak Time Max Flow L min L min Note The remote sensor probes use a Panasonic LRV08 A23 MN21 battery providing a nominal voltage of 12V These batteries are interchangeable with 23A 23GA E23A GP 23A GP23A K23A L1028 LR23A LRVO8 MS2...

Page 14: ...cock press the open button and then press the close button to switch off the valve again If the leak has been triggered by water touching one of the remote sensor probes the valve will close but there will be no audible alarm Look for a flashing red LED on the sensor that has detected the water this acts as a guide to help direct you to the location of the leak To reset the system dry the sensor wai...

Page 15: ... information A verification code will be sent to your email address Check the junk mail folder if you don t receive this Enter the name of your router and the password Click on NEXT MENU OPEN CLOSE Volume Time Leak Time Max Flow L min L min Press menu and close on the main alarm unit to activate the WiFi setting The WiFi symbol will illuminate Click on Add Device Your Imrita will appear showing tha...

Page 16: ...one continuous session Water Time The amount of water in minutes allowed to flow in any one continuous session Leak Time The amount of time water can flow at a slower flow rate used to detect smaller leaks Automatic Water Restore Time The length of time before the valve will automatically reopen after a leak has been detected if a valve or tap is not closed Automatic valve closing The length of time ...