9
— Case Rear —
Main
Power
“Rocker”
Switch
Temperature
Control Module
Drop-In
Refrigerated
Section
Condensate
Pan
DO3616R
DO4816R
Thermometer
Light Switch
— Case Front —
Electrical
Box
1. Case Start-Up
Plug cord into a certified electrical outlet with
ground.
Turn on the Main Power Switch. Switch is in the
Drop-In Refrigerated Section on the rear right
hand side of base.
The Temperature Control Module (LED) will
illuminate. Evaporator coil fans and the
compressor motor should turn on.
From the front of the case, raise the deck to
confirm that the coil fans are functioning
properly.
Turn on the lights. Light Switch is in the Upper
Display interior of the case at rear right side
(see illustration at right).
First time lighting may require a short warm up
period for the bulbs. Slightly dim or a flickering
of new bulbs is normal.
2. Temperature Settings
This case has been tested to maintain a
temperature at or below 5° Celsius /
41° Fahrenheit.
When the merchandiser is in a start up mode or
has been idle for a long period of time, the unit
will require 30 minutes in order to pull-down to
temperature.
The temperature is controlled by a Temperature
Control Module. It is located at the lower-right
area (from the case rear) of the Drop-In
Refrigerated Section. See top-right illustration
for general location.
If a temperature setting change is required,refer
to instructions in the temperature controller
section of this operating manual.
3. Thermometers
Either digital or spirit-filled thermometer are
located in the refrigerated compartment.
Thermometers are to reflect internal air
temperature only (not actual food temperature).
Use probe thermometers to determine actual
product temperatures.
See illustrations at right for both digital and spirit
filled thermometers.
—– Main Power “Rocker” Switch —–
OFF
ON
Spirit-Filled
Thermometer
—– Digital Thermometer —–