July 2001
Impro Technologies
Data subject to change without notice
Page 4
INTRODUCTION
The Improx DT Door Terminal forms part of the ImproX family of access control
equipment.
The unit provides two input sensors for door open/close sensing, and one relay for
controlling door strikes or other equipment. The unit also provides 5 VDC and TTL
communications for a Remote Reader such as the ImproX CR, KR, MR, KHR, MHR or
connects to an Impro 4-Channel UHF Receiver.
The unit communicates with other ImproX units via an RS485 Terminal Bus connection.
The Door Terminal is intended for indoor mounting only.
SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Dimensions
:
Length
Width
Height
=
=
=
105 mm (4.14").
116 mm (4.57").
54 mm (2.13").
Weight
:
115 g.
(4.05 oz).
Housing material
:
Aluminium.
Colour
:
Black.
ENVIRONMENTAL SPECIFICATIONS
TEMPERATURE
•
Operating
:
-25
o
C to +70
o
C (- 13
o
F to +158
o
F).
•
Storage
:
-40
o
C to +80
o
C (-40
o
F to +176
o
F).
HUMIDITY RANGE
:
0 to 95% relative humidity at 40
o
C (+104
o
F)
non-condensing.
EMC
:
EN55024.
ELECTROSTATIC DISCHARGE
:
IEC6 1000-4-2.
ELECTRICAL FAST TRANSIENTS
:
IEC6 1000-4-4.
SURGE IMMUNITY
:
IEC6 1000-4-5.
RADIATED SUSCEPTIBILITY
:
IEC6 1000-4-3.
CONDUCTED SUSCEPTIBILITY
:
IEC6 1000-4-6.
DUST AND SPLASH RESISTANCE
:
This unit is manufactured in accordance with a
dust and splash environment similar to that
required for a rating of IP30.
DROP ENDURANCE
:
1 m drop (in packaging).