background image

 

 

 

MODEL NUMBER:  

XDB902-1-0-GB-XX 
XDB903-1-0-GB-XX 

I

MPRO

X

 

DB

V

 

ImproX (DBv) Vertical Mount Drop Box                                                               

INSTALLATION MANUAL 

SPECIFICATIONS 

Read/Write Capability

 .................. 

 

Impro Tags:  All standard ImproX Credit Card 
Tags, with or without the slot and clip. 
Third-party Tags:  Read only capabilities on 
selected third-party Credit Card Tags. 

Working Environment 

 

 

XDB902-1-0-GB-XX ...............  

Mounted in a suitably rated, user supplied 
cabinet; the Drop Box is designed to work in 
an indoor or outdoor environment similar to 
IP54.   

 

XDB903-1-0-GB-XX ...............  

The Drop Box is designed to work in an indoor 
or outdoor environment similar to IP66.   

Input Voltage

 ................................ 

 

12 V DC, polarity sensitive. 

Power Requirements 

Current (mA) 

Power (W) 

 

Input Voltage 12 V DC 
Solenoid OFF .........................  

45 

0.54 

 

Input Voltage 12 V DC 
Solenoid ON ...........................  

800 

9.60 

Solenoid 

 

 

Input Voltage ..........................  

12 V DC. 

 

Type .......................................  

Push, pull action. 

Relays 

 

 

Relay Output ..........................  

2 Relays each with NO, COM and NC 
contacts. 

 

Relay Allocation 

 

 

Relay 1 ...........................  

Factory configured to drive the Solenoid when 
a Tag is inserted and read inside the Drop 
Box. 

 

Relay 2 ...........................  

User configured to control hardware at the exit 
point (typically a boom, vehicle gate or 
turnstile). 

 

Summary of Contents for IMPROX DBV

Page 1: ...or outdoor environment similar to IP54 XDB903 1 0 GB XX The Drop Box is designed to work in an indoor or outdoor environment similar to IP66 Input Voltage 12 V DC polarity sensitive Power Requirement...

Page 2: ...V continuous 80 V to 80 V surge LED Diagnostic Indicators Status LED Power On Continuous Red Upgrade Mode Flashing Red Steady RS485 Communications Failure Flashing Red Intermittent Incoming RS485 Dat...

Page 3: ...es a Tag Retention Box for catching the Tags The Drop Box Throat Assembly includes a 1 m 7 ft twisted black 0 5 mm 2 Conductor Power Cable One mild steel Mounting Bracket Two Keys Two PG7 Plastic Cabl...

Page 4: ...er ranges between 2 m to 16 m 7 ft to 53 ft Achieve this by using good quality screened twisted pair cable Distance between the Antenna Reader and the Drop Box To avoid mutual interference install the...

Page 5: ...the outside of the counter and the Throat Assembly is mounted on the inside of the counter CAUTION Make allowance during installation for the Tag Retention Box Ensure that the Tag Retention Box does N...

Page 6: ...e of the Drop Box 2 Mark out and drill the mounting hole 3 Fix the Drop Box into position using the Mounting Bracket and M10 Rawl Bolt 4 Remove the Face Plate Assembly including the Throat Assembly 5...

Page 7: ...off the lip located at position 1 see Figure 3 3 Turn the Tag Retention Box so that the lip faces away from the open Cabinet door 4 Hang the Tag Retention Box on the lip located at position 2 see Fig...

Page 8: ...0 GB 04 December 2007 Page 8 ELECTRICAL CONNECTIONS Typical Electrical Connections Figure 4 shows a typical electrical connection diagram for the ImproX DBv Figure 4 Typical ImproX DBv Electrical Con...

Page 9: ...ed Address Labels in the position of the Drop Box on the sketched site plan When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels fi...

Page 10: ...XDB300 0 0 GB 04 December 2007 Page 10 USER NOTES...

Page 11: ...XDB300 0 0 GB 04 December 2007 Page 11 USER NOTES...

Page 12: ...cable to the ImproX DBv Vertical Mount Drop Box XDB902 1 0 GB 02 and XDB903 1 0 GB 01 The last two digits of the Impro stock code indicate the issue status of the product XDB300 0 0 GB 04 Issue 05 Dec...

Reviews: