Basic functionality
REcOmmENDED SETTINgS
The following settings are recommended for different types of floor
constructions:
Top flooring
Program mode
Wooden
floor*
Tiled
floor**
1
(room sensor)
If total effect: 0W-1840W
x
2
(floor sensor)
If total effect: 0W-2990W
x
x
3
(combined floor and room sensor)
If total effect: 1840W-2990W
x
x
4
(room sensor)
If total effect: 1840W-2990W
x
5
(combined floor and room sensor)
If total effect 0W-1840W
x
x
* Final floor finish made of parquet, laminate, wood, carpet, linoleum
or similar.
** Final floor finish of tiles, concrete, marble or similar.