Flush Mount Installation Details:
MODELS:
MODELS:
MODELS:
G3000SD2
G3000SD4
G3000PS1
3000SD2
3000SD4
3000PS1
CABINET:
Be sure cabinet bottom is level, side to side and front to rear.
For the
“SD”
units prepare cabinet by cutting an 8” x 8” hole in bottom, 3/4” from wall
and on Center line.
For the
“PS1”
units prepare the cabinet by cutting a 10 3/8” (D) x 20 1/4” (W) hole in
the bottom, 1/2” from wall and center line.
Shelves and top to be cut to clear 7” round pipe. Make sure to cut holes for electrical
wires.
NOTE:
Bolts, washers and nuts supplied. Remove the Drawer before positioning the hood
under the cabinet.
(See next page on how to remove drawer.)
Remove Black Tape that holds dampers in closed posi-
tion. *It is NOT recommended to use 2 dampers during
installation. You have the option to put a external damper
or use the existing damper already on the unit.
Position hood against cabinet bottom and against the wall.
Mark the underside of cabinet through each key-hole for
location of each bolt hole.
Drill 3/16” holes through cabinet bottom. Insert bolts with small
washer under head of bolt through cabinet bottom from inside
the cabinet.
Again, position hood under cabinet with bolts through
key-holes. Starting with front key-holes, place large washer on
bolt, attach the wing-nut to bolt, secure both front wing-nuts.
Push hood back against wall, secure large washer and the
wing-nuts on rear bolts.
Re-install the drawer.
Connect duct and tape all joints.
Replace Filters
ELECTRICAL:
Bring enough wire into cabinet to reach in front of vent pipe.
Enter the cabinet 3 1/4” left of center for (SD unit) or 2 1/4” for the (PS1 unit).
Remove electrical box cover before mounting the hood.
After hood is mounted attach house wires to leads in hood.
Secure locknut to conduit and check wiring for compliance with all local codes.
Replace electrical box cover.
Units are to be hard wired. It is not recommended to add a power-cord. Adding a
power cord can loosen existing wires inside junction box causing electrical failure.
cord.
Duct Sizes Indicated in Model # (Ex: 3030PS1-8)
** - 8 = 8” DUCT PIPE
PROPERTY OF HOME OWNER, DO NOT THROW AWAY!
SD2 or SD4
PS1
Black Tape on Damper
Summary of Contents for 3000PS1
Page 15: ......