3

⍟ 

 

Do not use the unit in small spaces.

 

⍟ 

Do not put in places where water may 

splash onto the unit.

⍟     

Place the unit on a level, sturdy section 

of the floor.

• Lack of ventilation can cause overheating 

and fire.

• 

Water may enter the unit and degrade the 

insulation. It may cause an electric shock 

or fire.

• 

If the unit falls over, it may cause water 

to spill and damage belongings, or 

cause electrical shock or fire.

 

⍟ 

Do not cover the intake or exhaust open

-

ings with cloths or towels.

 

⍟ 

Care should be taken when using the unit 

in a room with the following persons:

⍟ 

 

Do not use in areas where chemicals 

 

are handled.

• 

A lack of air flow can lead to overheating 

and fire.

• Infants, children, elderly people, and peo

-

ple sensitive to dry environments.

• 

This will cause the unit deterioration due 

to chemicals and solvents 

 

dissolved in the air.

⍟ 

 

Never insert your finger or other foreign 

objects into grills or openings. Take special 

care to warn children of these dangers.

⍟ 

 

Do not place heavy object on the power 

cord and take care so that the cord is not 

compressed.

⍟ 

 

D

o not climb up on or sit on the unit.

• It may cause electric shock or failure of 

appliance.

• There is danger of fire or electric shock.

• 

You may be injured if you fall or 

 

if the unit falls over.

⍟   

Always insert the filters securely. 

 

Clean filter once every two weeks.

⍟ 

 

If water enters the unit, turn the unit off 

and disconnect the power , contact a quali

-

fied service technician.

⍟ 

 

Do not place flower vases or other 

 

water container on top of the unit.

• 

Operation without filters may cause failure

 .

• It may cause failure of appliance or acci

-

dent .

• Water may spill inside the unit, causing 

insulation failure and electrical shock 

or fire.

CAUTION

UNIT DIAGRAM:

                                  FRONT VIEW                                                                                              REAR VIEW 

1 . 

Control panel

2 . 

Air intake grille

3 . 

Air outlet grille

4 . 

Air filter (behind the grille)

5 . 

Water reservoir

6 . 

Handle (both sides)

7 . 

Water level window

8 . 

Drain hose outlet

9 . 

Rolling casters

10 . 

Power cord and plug

11 . 

Band (used only when storing unit)

5

1

2

3

4

6

7

8

3

9

10

11

12

NOTE:

 All drawings in this manual are 

for illustrative purposes only. The actual 

shape of the unit you purchased may be 

slightly different, but the operations and 

functions are the same.

Fig. 1

Fig. 2

Summary of Contents for IDM-30SE

Page 1: ...i Impecca Dehumidifier User s Manual IDM 30SE 30 Pint Dehumidifier IDM 45SE 45 Pint Dehumidifier IDM 70SE 70 Pint Dehumidifier...

Page 2: ...or disposal at least free of charge to the user D As old products contain valuable resources they can be sold to scrap metal dealers Wild disposal of waste in forests and landscapes endangers your hea...

Page 3: ...batteries and AC adaptors Impecca reserves the right to repair or replace defective products with the same equivalent or newer models We reserve the right to either repair or replace product at our d...

Page 4: ...tacle is accessible after the unit installation Do not exceed the rating of the power outlet or connection device Do not operate or stop the unit by switching on or off the power Do not damage or use...

Page 5: ...rd and take care so that the cord is not compressed Do not climb up on or sit on the unit It may cause electric shock or failure of appliance There is danger of fire or electric shock You may be injur...

Page 6: ...aters or radiators Use the unit to prevent moisture damage anywhere books or valuables are stored The dehumidifier should be operated in an enclosed area to be most effective Close all doors windows a...

Page 7: ...he unit may be completely silent 3 CONTINUOUS MODE In continuous mode the unit s compressor will run continuously until the unit is powered off or another mode is selected This will remove all the moi...

Page 8: ...the reservoir you should wipe it dry CONTINUOUS DRAINAGE Water can be automatically emptied into a floor drain or any drain locat ed lower than the dehumidifier itself by attaching a standard garden...

Page 9: ...minate This will provide a quicker dehumidification Ideal for situations where speedy removal of moisture is more important than quiet operation RESERVOIR FULL LIGHT Illuminates when the reservoir is...

Page 10: ...an ing the reservoir must be in place and securely seated for the dehumidifier to operate CLEANING THE AIR FILTER Clean the filter every two weeks based on normal operating con ditions 1 Remove the re...

Page 11: ...ears on the coils This is normal The dehumidifier has an auto defrost feature Water on floor Hose to connector or hose connection may be loose Even though you re using the reservoir the back drain plu...

Page 12: ...2016 Impecca a division of LT Inc Wilkes Barre PA...