Impco ET98 Quick Start Manual Download Page 2

 

 

 

PPI-118 REV. C                                                 IMPCO Technologies Inc                                                         April, 2013 
Page 2 of 2 

                                  3030 South Susan St. 

Santa Ana, CA 92704 

www.impcotechnologies.com

 

 

 

 

O-Rings included in the RK-ET98.  (Not to scale--use relative size to de-
termine application) 
 

Item

Part #

Description

1

NSS

Valve Body

 2*

NSS

O-ring

3

NSS

Bracket

 4*

NSS

O-ring

5*

NSS

Filter

 6*

NSS

O-ring

 7*

NSS

O-ring

8

NSS

Filter Bowl

 9*

NSS

O-ring

10

NSS

Bolt

 

*Included in Repair Kit 
Note: The parts are called out by number and designated by parentheses () in 
the Rebuild Instructions. 

 

 

WARNING: 

IMPROPER INSTALLATION OR USE OF THIS PRODUCT MAY CAUSE SERIOUS INJURY 

AND/OR PROPERTY DAMAGE. 

THE FOLLOWING IS SPECIFIC TO USA AND CANADA.  IF INSTALLED, REPAIRED OR MAINTAINED OUTSIDE OF THE USA OR CANADA, 
REFER TO LOCAL STANDARDS AND LAWS GOVERNING THIS AND RELATED PRODUCTS.  

CANADA:  

REFER TO CAN/CGA PROPANE 

INSTALLATION CODES. 

 

SERVICE TECHNICIANS AND USERS 

SHOULD CAREFULLY READ AND ABIDE BY THE PROVISIONS SET FORTH IN NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET 
#37 FOR STATIONARY ENGINES, #52 FOR CNG VEHICULAR FUEL SYSTEMS OR #58 FOR LPG SYSTEMS. 

 

INSTALLERS 

LPG INSTALLATIONS IN THE UNITED STATES MUST BE DONE IN ACCORDANCE WITH FEDERAL STATE OR LOCAL LAW, WHICHEVER IS 
APPLICABLE AND NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET #58, STANDARD FOR STORAGE AND HANDLING OF LIQUE-
FIED PETROLEUM GASES TO THE EXTENT THESE STANDARDS ARE NOT IN VIOLATION WITH FEDERAL, STATE OR LOCAL LAW.  

CANADA:  

REFER TO CAN/CGA PROPANE INSTALLATION CODES. 

 

CNG INSTALLATIONS IN THE UNITED STATES/CANADA

 

MUST RE DONE IN ACCORDANCE WITH FEDERAL STATE OR LOCAL LAW AND NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET 
#52, COMPRESSED NATURAL GAS (CNG) VEHICULAR FUEL SYSTEMS TO THE EXTENT THESE STANDARDS ARE NOT IN VIOLATION 
WITH FEDERAL, STATE OR LOCAL LAW.  

CANADA: 

REFER TO CAN/CGA CNG INSTALLATION CODES. 

 

LPG AND/OR NATURAL GAS INSTALLATIONS ON STATIONARY ENGINES 

MUST RE DONE IN ACCORDANCE WITH FEDERAL, STATE OR LOCAL LAW AND NATIONAL FIRE PROTECTION ASSOCIATION PAMPHLET 
#37, STATIONARY COMBUSTION ENGINES AND GAS TURBINE ENGINES, TO THE EXTENT THESE STANDARDS ARE NOT IN VIOLATION 
WITH FEDERAL, STATE OR LOCAL LAW. FAILURE TO ABIDE BY THE ABOVE WILL VOID ANY IMPCO WARRANTY ON THE PRODUCTS 
AND MAY CAUSE SERIES INJURY OR PROPERTY DAMAGE.  DUE TO THE INHERENT DANGER OF GASEOUS FUELS THE IMPCO PROD-
UCTS SHOULD NOT BE INSTALLED OR USED BY PERSONS NOT KNOWLEDGEABLE OF THE HAZARDS ASSOCIATED WITH THE USE OF 
GASEOUS FUELS. 

Reviews: