UNPACKING AND OPERATING INSTRUCTIONS

Unpacking
Caution!

This packaging contains sharp objects.

Take care when unpacking. Remove the
machine, together with the accessories
supplied, from the packaging. Check carefully to
ensure that the machine is in good condition
and account for all the accessories listed in this
manual. Also make sure that all the accessories
are complete. If any parts are found to be
missing, the machine and its accessories should
be returned together in their original packaging
to the retailer.

Do not throw the packaging away, keep it safe
throughout the guarantee period, then recycle if
possible, otherwise dispose of it by the proper
means. Do not let children play with empty
plastic bags due to the risk of suffocation.

Operating Instructions

Location and Grounding

Before using this generator it must be prepared
correctly before use. Locate the generator on
firm level ground away from buildings or other
structures ensuring that the exhaust is not
obstructed.

Warning!

It is advisable to properly earth-

ground your generator before starting using a
wire and a small earth stake. Note: The wire and
earth stake are not supplied with the unit.

Earth spike and cable can be purchased at your
local camping supplies, or alternatively an earth
spike can be made, and it is suggested you get
advice from a registered electrical trades
person. To make a spike use a copper tube or
copper rod 12mm diameter, a minimum length
of 200mm and with an M6 machine screw one
end. The cable used should be a maximum
length of 1 metre and a minimum of 1.0mm

2

to

carry a 10amp load. The cable should be
attached to the generator at the earth point
(Fig 1) and to the spike between a flat washer
and the copper with a lock washer under the
head of the M6 Machine screw in a similar
fashion to the earth point screw on the
generator.

When placing the spike into the ground the
generator must not be running and it is
suggested that the spike is pushed into the
ground by at least 100mm so that it is firm and

a litre of water poured around it to ensure good
earth continuity.

Checking The Oil
Warning!

The generator is supplied without oil

and must be filled before first use, failure to do
so will invalidate your guarantee. Loosen the
cover screw and remove the maintenance cover.

Remove the oil filler cap and wipe the dipstick
clean, Fig 2.

Fig 1

Fig 2

Max oil level

Summary of Contents for IM800I

Page 1: ...DOCUMENTATION HOLDER 4HE TECHNICAL DOCUMENTATION REQUIRED TO DEMONSTRATE THAT THE PRODUCT MEETS THE REQUIREMENTS OF DIRECTIVE HAS BEEN COMPILED AND IS AVAILABLE FOR INSPECTION BY THE RELEVANT ENFORCE...

Page 2: ...Always Read Instruction Manual Retain for Future Reference IM800I 780W INVERTER GENERATOR...

Page 3: ...adequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable for...

Page 4: ...or touch with wet hands Check the fuel system periodically for leaks seals and hoses should be checked for signs of deterioration or chafing Check for loose or missing clamps damaged fuel tank or fil...

Page 5: ...match the outlet Never modify the plug in any way Do not use any adapter plugs with earthed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body...

Page 6: ...sures reduce the risk of starting the power tool accidentally d Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to ope...

Page 7: ...AP UEL TANK VENT TAP 3PARK PLUG MAINTENANCE COVER XHAUST CHARGING LEADS 3CREWDRIVER 3PARK PLUG SPANNER 4ECHNICAL SPECIFICATION OUTPUT 6 Z 2ATED POWER 7 0EAK POWER 7 0HASE 3INGLE 0OWER FACTOR COS ISPLA...

Page 8: ...nd a small earth stake Note The wire and earth stake are not supplied with the unit Earth spike and cable can be purchased at your local camping supplies or alternatively an earth spike can be made an...

Page 9: ...engine is certified to operate on unleaded gasoline Unleaded gasoline produces fewer engine and spark plug deposits and extends exhaust system life Warning Never use stale or contaminated gasoline or...

Page 10: ...APPLIANCE BEING CONNECTED IS IN GOOD WORKING ORDER AND THAT THE MAINS SUPPLY LEAD IS LONG ENOUGH TO REACH THE GENERATOR WITHOUT ANY STRAIN 7HEN THE GENERATOR ENGINE HAS BEEN SUCCESSFULLY STARTED AND...

Page 11: ...economy and reduced noise levels when under no load conditions When a load is connected to the generator the generator speed will automatically adjust in order to supply enough power Appliances with l...

Page 12: ...NORMAL THE 2ED OVER LOAD INDICATOR EXTINGUISHES AFTER ABOUT FOUR SECONDS F THE 2ED OVERLOAD INDICATOR REMAINS ILLUMINATED CONSULT YOUR GENERATOR DEALER AUTION 3UBSTANTIAL OVERLOADING THAT CONTINUOUSLY...

Page 13: ...s threading After the spark plug is seated tighten with a spark plug wrench to compress the washer If installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer If...

Page 14: ...oughly using an environmentally friendly water based degreasing agent and re fit Air Filter Fig 21 A dirty air cleaner will restrict air flow to the carburettor To prevent carburettor malfunction serv...

Page 15: ...imately one tablespoon full of clean engine oil into the spark plug hole With the ignition turned OFF gently pull on the recoil starter cord several times Re fit the spark plug and continue to pull th...

Page 16: ...15 TROUBLESHOOTING...

Page 17: ...TROUBLESHOOTING 16...

Page 18: ...ling Check fan damage system Starting Check recoil starter system operation Decarbon More frequently isation if necessary Fittings Check all fittings and fixtures Fastenings and tighten if required Th...

Page 19: ...sposing of this product correctly will help to save valuable resources and prevent any potential adverse effects on human health and the environment which could otherwise arise from inappropriate wast...

Page 20: ...ECYCLE WHERE FACILITIES EXIST HECK WITH YOUR OCAL UTHORITY OR RETAILER FOR RECYCLING ADVICE ENERAL WARNING 7EAR HEARING PROTECTION 7EAR EYE PROTECTION 7EAR RESPIRATORY PROTECTION 54 4HIS IS A STROKE E...

Reviews: