background image

IMPORTANT SAFETY INFORMATION

Do not operate generator when you are tired or
under the influence of drugs, alcohol, or
medication.

The electrical output load must not exceed the
maximum load stated on the rating plate.
Exceeding the rated load will damage the unit or
shorten its life and will invalidate the guarantee.

The engine must not be run at speeds that
exceed the maximum stated on the rating plate.

Operating an engine at excessive speeds
increases the hazard of personal injury.

Do not tamper with components, which may
increase or decrease the governed speed.

Mains extension leads, mains supply leads, and
all electrical equipment must be in good working
condition.

Never operate electrical equipment with
damaged or defective mains supply leads.

Keep the area around the generator clear of
obstructions at all times. Never locate the
generator against a building or near a canvas or
plastic structure i.e.Tents etc.

Always use the correct fuel mix as stated in the
user manual and on the rating plate.

To reduce the risk of fire and burn injury, handle
fuel with care. It is highly flammable.

Do not smoke while handling fuel.

Store fuel in a container approved for gasoline.

To prevent fire, always stop the engine and allow
to cool for five minutes before refueling and
never over fill the fuel tank.

Loosen fuel cap slowly to release pressure and
to keep fuel from escaping around the cap.

Tighten the fuel cap securely after refueling.

Wipe spilled fuel from the unit.

Never attempt to burn off spilled fuel under any
circumstances.

Always clean up spilt fuel immediately using
sand.

Do not use the generator in or near an explosive
atmosphere.

To prevent an electric shock, never operate the
machine in rain, snow or touch with wet hands.

Check the fuel system periodically for leaks.
Seals and hoses should be checked for signs of
deterioration or chafing. Check for loose or
missing clamps damaged fuel tank or filler cap.
All defects should be corrected before further
use.

Always allow the generator to reach full
operating speed before connecting any
electrical load. Always disconnect the electrical
load before switching the generator off.

To prevent surging that may possibly damage
electrical equipment, do not allow engine to run
out of fuel while electrical loads are connected.

Before transporting the generator in a vehicle,
drain all fuel to prevent spillage.

To prevent an electric shock and fire, never
connect an electrical load with the electrical
output switched on.

Do not connect the generator to any other
electrical source.

Before storing, allow the engine to cool for 30
minutes and drain fuel from the unit.

Do not store the generator in rain, snow, or wet
weather.

Store the generator in a well-ventilated area with
the fuel tank empty. Fuel should not be stored
near the generator.

Empty fuel tank, place the engine switch/fuel
valve/choke lever in the OFF position, and
restrain the unit from moving before transporting
in a vehicle.

Provide a plastic sheet or absorbent pad below
the generator to catch any drips of fuel or
lubricant when transporting.

Generators vibrate in normal use. During and
after the use of the generator, inspect the
generator as well as extension cords and power
supply cords connected to it for damage
resulting from vibration. Have damaged items
repaired or replaced as necessary. Do not use
plugs or cords that show signs of damage such
as broken or cracked insulation or damaged
blades.

4

Summary of Contents for IM1800IFG

Page 1: ...designated standards used or references to the other technical specifications in relation to which conformity is declared 7 The person authorized to compile the technical file Name Robert Redfern Addr...

Page 2: ...Always Read Instruction Manual Retain for Future Reference IM1800IFG 1800W INVERTER GENERATOR...

Page 3: ...adequately packed to prevent transit damage and must be accompanied with a brief description of the fault and a copy of the receipt or other proof of purchase The manufacturer shall not be liable for...

Page 4: ...carbon monoxide can build up in these areas Using a fan or opening windows and doors does NOT supply enough fresh air ONLY use a generator outdoors and far away from open windows doors and vents These...

Page 5: ...r near an explosive atmosphere To prevent an electric shock never operate the machine in rain snow or touch with wet hands Check the fuel system periodically for leaks Seals and hoses should be checke...

Page 6: ...filler cap by hand as securely as possible Before use always make sure that the fuel cap has been properly tightened Check for fuel leakage while refuelling and during operation If a fuel leak is susp...

Page 7: ...electrical system unless a transfer switch has been properly installed by a qualified electrician Do not allow the generator s fuel tank to overflow when filling Fill to 25mm below the top neck of th...

Page 8: ...AC socket Right side 3 Oil alert indicator yellow 4 AC power indicator green 5 Economy control switch 6 Engine On Stop switch 7 Engine overload indicator red 8 Air filter cover connection screw 9 Air...

Page 9: ...COMPONENTS 8 14 13 12 15 Component List 12 Spark plug cap 13 Choke lever 14 Fuel valve 15 Oil filler cap dipstick 16 Recoil starter grip 16...

Page 10: ...OHV No load speed low 2800min 1 No load speed high 3300min 1 Rated load speed 3800min 1 Continuous operating time 10hrs 70 load Fuel tank capacity 10L Fuel type Unleaded petrol Oil type SAE 10W 30 Oil...

Page 11: ...s fully stopped and the generator is situated on a stable and level surface ADDING ENGINE OIL Engine oil has a major influence on engine performance and service life For general all temperature use SA...

Page 12: ...operly earth ground your generator before starting using a wire and a small earth stake Note The wire and earth stake are not supplied with the unit Earth spike and cable can be purchased at your loca...

Page 13: ...rip check the engine oil level 4 AC power indicator light green It indicates that the generator is producing electrical power at the sockets 5 Economy control switch When turned to the ON position the...

Page 14: ...4 times to let the engine breath in the fuel mixture from the carburetor Pull the cord sharply Continue this procedure until the engine starts CAUTION Avoid damaging the plastic case of the crankshaf...

Page 15: ...y are connected to the generator Turn the economy switch to the Off position and connect the appliance to the generator If the engine still will not reach normal operating speed check that the applian...

Page 16: ...Place the generator on a level surface and warm up the engine for several minutes Stop the engine 2 Remove the oil filler cap dipstick 3 Place a container under the engine Tilt the generator to drain...

Page 17: ...opriate amount If reusing old spark plug use 1 8 to 1 4 turn for proper washer compression 7 Replace spark plug cap WARNING Spark plug must be assembled firmly or it will become hot and may damage gen...

Page 18: ...top puling Store the generator in a dry well ventilated place under a cover to prevent any dust or debris from accumulating on the generator DRAINING THE CARBURETOR 1 Turn off fuel valve make sure fue...

Page 19: ...mage system Starting Check recoil starter system operation Decarbon More frequently isation if necessary Fittings Check all fittings and fixtures Fastenings and tighten if required STORAGE STORAGE TIM...

Page 20: ...19 TROUBLESHOOTING...

Page 21: ...oduct Disposing of this product correctly will help to save valuable resources and prevent any potential adverse effects on human health and the environment which could otherwise arise from inappropri...

Page 22: ...noxide an odourless colourless poison gas Breathing carbon monoxide can cause nausea fainting or death Fuel and its vapours are extremely flammable and explosive Fire or explosion can cause severe bur...

Page 23: ...22 NOTES...

Page 24: ...23 NOTES...

Page 25: ...24 NOTES...

Page 26: ...ap Brands Ltd Office 20 Fleming Court Business Centre Leigh Road Eastleigh Hampshire SO50 9YN Signed for and on behalf of Authorised Representative Robert Redfern Technical Manager 04 03 2021 2006 42...

Page 27: ...W 40 4 STROKE ENGINE OIL ONLY The oil level should fall within the level indicator area on the dipstick Overfilling this generator with oil will cause serious damage and will invalidate your warranty...

Page 28: ...ator Product Helpline If you experience any problems with your IMPAX generator please contact the helpline who can offer fault finding technical support and general guidance Technical Helpline Number...

Reviews: