37
2-5-3. MENU > NETWORK > Notification
In Callback, set up IP addresses of client sites so
that Events detected in local system can be notified
to multi remote client sites simultaneously. Enter IP
addresses of client sites to receive events
notifications on remote sites. Press
to pop up
the virtual keyboard.
Callback Interval
: Select Callback Interval to set
time interval between consequential events
being sent to remote site.
Port :
Set
UDP
port that transmits DVR‟s event information to Client sites.
Note
: Any events occur between the pre-set interval time will not be sent to remote site. e.g. If the
interval is set as 30 seconds, only the events occur every 30 seconds since the first event will be sent
to remote site.
In Email, Events can be notified to personal email addresses by text message.
E-Mail Interval
: Select E-Mail Interval to set time interval between consequential events being sent
to remote site via email.
Recipient
: Enter the email address of a recipient. Up to 5 recipients can be entered.
Note
: Any events occur between the pre-set interval time will not be sent to remote site. e.g. If the
interval is set as 30 seconds, only the events occur every 30 seconds since the first event will be sent
to remote site via email.
SMTP Server
: Enter SMTP server using the virtual keyboard. SMTP server information can be
obtained from a system administrator.
Sender
: Enter the address/name where the email is being sent from.
2-5-4. MENU > NETWORK > Transmission
In Transmission, Network transmission can be
controlled with ips and bandwidth.
Note
: Max. ips on Network transmission is
120ips@16ch-DVR, 60ips@8ch-DVR and
60ips@4ch-DVR.(NTSC)