Impact Test Equipment MH630 User Manual Download Page 7

 
 

 

MH630 240V / MH631 110V Vibrating Hammer  

MH630 

5. 

Be sure the bit is secured in place before operation. 

6. 

Under normal operation, the tool is designed to produce vibration. The screws can come loose 
easily, causing a breakdown or accident. Check tightness of screws carefully before operation. 

7. 

In cold weather or when the tool has not been used for a long time, let the tool warm up for a 
while by operating it under no load. 

This will loosen up the lubrication. Without proper

 

warm-up, 

hammering operation is difficult.  

8. 

Always be sure you have a firm footing. 

Be sure no one is below when using the tool in high 

locations. 

9. 

Hold the tool firmly with both hands. 

10. 

Keep hands away from moving parts. 

11. 

Do not leave the tool running. 

Operate the tool only when hand-held.

 

12. 

Do not point the tool at any one in the area when operating. 

The bit could fly out and injure 

someone seriously. 

13. 

Do not touch the bit or parts close to the bit immediately after operation; they may be 
extremely hot and could burn your skin. 

14. 

Do not operate the tool at no-load unnecessarily. 

15. 

Some material contains chemicals which may be toxic. Take caution to prevent dust inhalation 
and skin contact. 

Follow material supplier safety data. 

 

 

SAVE THESE INSTRUCTIONS. 

WARNING: 
DO NOT let comfort or familiarity with product (gained from repeated use) replace strict adherence 
to safety rules for the subject product. 
MISUSE or failure to follow the safety rules stated in this instruction manual may cause serious 
personal injury. 
 

FUNCTIONAL DESCRIPTION 

CAUTION: 

 

Always be sure that the tool is switched off and unplugged before adjusting or checking function 
on the tool. 

 

Switch action 

1. Switch lever 
 
 
 
 

CAUTION: 

 

Before plugging in the tool, always check to see that the tool is switched off. 

 

Switch can be locked in "ON" position for ease of operator comfort during extended use. Apply

 

caution when locking tool in "ON" position and maintain firm grasp on tool. 

 

To start the tool, push the switch lever "ON (I)" on the left side of the tool. To stop the tool, push 
the switch lever "OFF (O)" on the right side of the tool. 

OFF 

ON 

Summary of Contents for MH630

Page 1: ...Vibrating Hammer Makita 240V 110V MH630 MH631 Impact Test Equipment Ltd www impact test co uk www impact test com User Guide User Guide ...

Page 2: ...pment Ltd Building 21 Stevenston Industrial Estate Stevenston Ayrshire KA20 3LR Tel 01294 602626 Fax 01294 461168 sales impact test co uk Test Equipment www impact test co uk Test Sieves Accessories www impact test com ...

Page 3: ...uipment together with household waste material In observance of European Directive 2002 96 EC on waste electric and electronic equipment and its implementation in accordance with national law electric equipment that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility Intended use The tool is intended for chiselling work i...

Page 4: ...ure WARNING The vibration emission during actual use of the power tool can differ from the declared emission value depending on the ways in which the tool is used Be sure to identify safety measures to protect the operator that are based on an estimation of exposure in the actual conditions of use taking account of all parts of the operating cycle such as the times when the tool is switched off an...

Page 5: ...shock 7 Do not abuse the cord Never use the cord for carrying pulling or unplugging the power tool Keep cord away from heat oil sharp edges or moving parts Damaged or entangled cords increase the risk of electric shock 8 When operating a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock 9 If operating a powe...

Page 6: ...ned users 22 Maintain power tools Check for misalignment or binding of moving parts breakage of parts and any other condition that may affect the power tool s operation If damaged have the power tool repaired before use Many accidents are caused by poorly maintained power tools 23 Keep cutting tools sharp and clean Properly maintained cutting tools with sharp cutting edges are less likely to bind ...

Page 7: ...tely after operation they may be extremely hot and could burn your skin 14 Do not operate the tool at no load unnecessarily 15 Some material contains chemicals which may be toxic Take caution to prevent dust inhalation and skin contact Follow material supplier safety data SAVE THESE INSTRUCTIONS WARNING DO NOT let comfort or familiarity with product gained from repeated use replace strict adherenc...

Page 8: ...to 1 Do not force it past 5 or 1 or the speed adjusting function may no longer work Indicator lamp 1 Power ON indicator lamp green 2 Service indicator lamp red The green power ON indicator lamp lights up when the tool is plugged in If the indicator lamp does not light up the mains cord or the controller may be malfunctioning The indicator lamp is lit but the tool does not start even if the tool is...

Page 9: ...tion and then tighten it by turning clockwise Installing or removing the bit 1 Bit shank 2 Bit grease Clean the bit shank and apply bit grease before installing the bit Insert the bit into the tool Turn the bit and push it in until it engages 1 Releasing cover If the bit cannot be pushed in remove the bit Pull the releasing cover down a couple of times Then insert the bit again Turn the bit and pu...

Page 10: ...ations Turn the tool on and apply slight pressure on the tool so that the tool will not bounce around uncontrolled Pressing very hard on the tool will not increase the efficiency MAINTENANCE CAUTION Always be sure that the tool is switched off and unplugged before attempting to perform inspection or maintenance Never use gasoline benzine thinner alcohol or the like Discoloration deformation or cra...

Page 11: ... can cause faulty hammering action or tool failure Fill only with the specified amount of grease 1 Grease CAUTION Be careful not to damage the connector or lead wires especially when wiping out the old grease To reassemble the tool follow the disassembling procedure in reverse CAUTION Do not tighten the crank cap excessively It is made of resin and is subject to breakage Be careful not to damage t...

Page 12: ...ther accessories or attachments might present a risk of injury to persons Only use accessory or attachment for its stated purpose If you need any assistance for more details regarding these accessories please contact Impact Test Equipment Spare Parts Available Bull point SDS max Cold chisel SDS max Scaling chisel SDS max Clay spade SDS max Bit grease Safety goggles Hammer grease Plastic carrying c...

Page 13: ...Impact Test Equipment Ltd Building 21 Stevenston Industrial Estate Stevenston Ayrshire KA20 3LR United Kingdom 44 01294 602626 www impact test co uk sales impact test co uk ...

Reviews: