Extensions for Ø 80/125 vertical kit (Fig. 21)
The kit with this configuration can be extended to a max. straight
vertical length of 32 m, including the terminal. If additional com-
ponents are assembled, the length equivalent to the maximum al-
lowed must be subtracted. In this case specific extensions must be
requested.
C
33
21
1.18 SEPARATOR KIT INSTALLATION
Type C configuration, sealed chamber and fan assisted, separator kit Ø 80/80
This kit allows air to come in from outside the building and the exhaust to exit from the chimney, flue or intubated duct through divided
flue exhaust and air intake pipes.
Combustion products are expelled from pipe (S) (in plastic, so as to resist acid condensate).
Air is taken in through duct (A) for combustion (this is also in plastic).
The intake pipe (A) can be installed either on the right or left hand side of the central exhaust pipe (S).
Both ducts can be routed in any direction.
Mounting the separator kit Ø 80/80 (Fig. 22):
1. Install the flange (4) on the central hole of the boiler, positioning gasket (1) with the circular projections downwards in contact with
the boiler flange.
2. Tighten with the hexagonal head and flat point screws provided in the kit.
3. Replace the flat flange present in the lateral hole with respect to the central one (according to needs) with the flange (3), positioning the
gasket (2) already present in the boiler
4. Tighten with the supplied self-tapping screws with drill bit.
5. Fit the bends with male side (smooth) (5) in the female side of the flanges (3 and 4).
6. Fit the intake terminal (6) with the male side (smooth) in the female side of the bend (5) up to the end stop, ensuring that the internal
and external wall sealing plates are fitted
7. Fit the exhaust pipe (9) with the male end (smooth) to the female end of the bend (5) up to the end stop; making sure that the internal
wall sealing plate has been fitted, this will ensure sealing and joining of the elements making up the kit.