In order to access parameters “n” and “S” press the “
”
button sequentially. In order to exit this part of the menu and
access other parts (categories P, t, A, F) press the “
” button.
-
IL.
Th
e “IL” gas type is not used; to exit, press “
”. If the
“IL” GAS is memorised, you must memorise the correct type
of GAS again.
Id
Parameter
Parameter
Description
Range
Default
Customised
value
n
Boiler model
Define the boiler model
0
÷
n
16
Caution:
only use the parameter relating to the boiler installed.
In the event of an alteration, anomaly “E62” appears and complete calibration is required.
Id
Parameter
Parameter
Description
Range
Default
Customised
value
G
Gas type
Defines operation with methane gas
nG
nG
Defines operation with LPG gas
LG
Not used
IL
In the event of an alteration, anomaly “E62” appears and complete calibration is required.
Id
Parameter
Parameter
Description
Range
Default
Customised
value
P0
DHW max
Defines the maximum heat output percentage of the boiler during
the D.H.W. phase compared to the maximum heat output available
0 - 99
%
99
%
P1
Min output
Defines the minimum heat output percentage of the boiler compared
to the minimum heat output available
0 - P2
0
%
P2
Central heating
max
Defines the maximum heat output percentage of the boiler during the
central heating mode compared to the maximum heat output available
0 - 99
%
80
%
P3
Relay 1
(optional)
Th
e boiler is set-up for functioning with the relay board (optional),
which can be configured
0
=
Off
1
=
Main zone control
2
=
General alarm
3
=
CH mode active
4
=
External gas valve power supply
5
=
(Do not use on this boiler model)
6
=
(Do not use on this boiler model)
7
=
(Do not use on this boiler model)
0 - 7
1
P4
Relay 2
(optional)
Th
e boiler is set-up for functioning with the relay board (optional),
which can be configured
0
=
Off
1
=
General alarm
2
=
CH phase mode
3
=
External gas valve power supply
4
=
Secondary zone control (from TA on relay board contact)
5
=
Heat pump
6
=
(Do not use on this boiler model)
7
=
(Do not use on this boiler model)
0 - 7
0
Id
Parameter
Parameter
Description
Range
Default
Customised
value
S0
Min output
Th
e P.C.B. defines the operating mode and the boiler output accord-
ing to the combination of several parameters.
Th
e proper operating
output of the appliance is defined according to the combination of
the parameters of menus “n” and “F”.
For this reason it is recommended not to alter the parameters of
this menu in order not to compromise the proper operation of the
boiler.
750
÷
1700
rpm
1150
S1
Max output
S0
÷
6900
rpm
3200
S2
Ignition output
2000
÷
4500
rpm
6200
In the event of an alteration, anomaly “E62” appears and complete calibration is required.