2.4 USER SETTINGS
Press the
button to enter the navigation menu.
Press buttons
until selecting menu “02. SET.
USER”.
Fig. 2-6
N a v i g a t i o n m e n u
01. SET-POINT
02.
USER SETTING
03.
TIME PROGRAMS
Press the
button to enter the menu.
- Party mode.
Activating the party mode sets all zones
in “Comfort” mode until the next programmed status
change. The central heating or cooling mode will de-
pend on the system state.
U s e r s e t t i n g
D 0 1
Party mode: No
Fig. 2-7
U s e r s e t t i n g
D 0 2
Gas prices
Gas type:
Methane
Methane:
000.00 c€/m
3
LPG:
000.00 c€/m
3
Fig. 2-8
-
Gas prices.
It lets you enter gas prices, also selecting
GAS type (methane/LPG). These data allow the sys-
tem manager to calculate the working point with the
maximum efficiency between heat pump operation and
GAS boiler.
U s e r s e t t i n g
D 0 3
Electric energy prices
Elet.F1:
000.00 c€/kWh
Elet.F2:
000.00 c€/kWh
Elet.F3:
000.00 c€/kWh
Fig. 2-9
-
Electricity prices.
It lets you enter electricity prices.
U s e r s e t t i n g
D 0 4
Energy band time
Tariff:
Two part
F1:
00:00 - 00:00
F2:
00:00 - 00:00
Fig. 2-10
-
Time slots.
Allows selecting between Dual-rate and
Multi-rate tariff, enter the time slots related to the
electricity prices.
-
Dual.
You can set the two daily time slots, the F1 and
F2 tariffs are valid from Monday to Friday while the
F2 tariff is applied to Saturday and Sunday.
-
Multi-rate.
You can set the three daily time slots, the
F1, F2 and F3 tariffs are valid from Monday to Friday
while the F2 tariff is applied to Saturday and Sunday.
-
Heat pump manual disabling
. The option lets you
permanently disable heat pumps as the main generator.
Heat pump temporary enabling
. The option lets you
enable heat pumps according to the time slots.
U s e r s e t t i n g D 0 5
Heat pump manual
disable comand:
No
Heat pump tempor.
enable comand:
No
Fig. 2-11
Press button
for the option “Disable heat pumps”
to start blinking.