  WATER HEATER INSTALLA-

TION

1.1  INSTALLATION RECOMMENDA-

TIONS.

The Julius water heater has been designed for wall 

installation. It must be used for the production 

of domestic hot water and similar purposes. 

In the case of wall installation the wall surface 

must be smooth, without any protrusions or 

recesses enabling access to the rear part. They 

are not designed to be installed on plinths or 

floors (Fig. 1-1).
The place of installation of the appliance and 

relative Immergas accessories must have suitable 

features (technical and structural) such to allow 

(always in safety, efficiency and comfortable 

conditions):

-  installation (according to the provisions of the 

technical legislation and technical regulations);

-  maintenance operations (including scheduled, 

periodic, routine and special maintenance);

- removal (to outdoors in the place for loading 

and transporting the appliances and compo-

nents) as well as their eventual replacement 

with appliances and/or equivalent components.

Only professionally enabled companies are 

authorised to install Immergas gas appliances. 

Installation must be carried out according to 

regulation standards, current legislation and in 

compliance with local technical regulations and 

the required technical procedures.
Before installing the appliance, ensure that it is 

delivered in perfect condition; if in doubt, contact 

the supplier immediately. Packing materials (sta-

ples, nails, plastic bags, polystyrene foam, etc.) 

constitute a hazard and must be kept out of the 

reach of children. 
If the appliance is installed inside or between 

cabinets, ensure sufficient space for normal ser-

vicing; therefore it is advisable to leave clearance 

of at least 3 cm between the water heater casing 

and the vertical sides of the cabinet. Leave ad-

equate space above the water heater for possible 

water and flue removal connections.
Keep all flammable objects away from the ap-

pliance (paper, rags, plastic, polystyrene, etc.).

It is recommended not to position household 

appliances under the water heater because they 

could undergo damage in the case of leaks from 

the hydraulic fittings. If this is not the case, the 

manufacturer cannot be considered liable for 

any damage caused to the household appliances.

For the aforementioned reasons, we recommend 

not placing  furnishings, furniture, etc. under 

the water heater. 

In the event of malfunctions, faults or incorrect 

operation, turn the appliance off and contact an 

authorised company (e.g. the Authorised Tech-

nical Assistance centre, which has specifically 

trained staff and original spare parts). Do not 

attempt to modify or repair the appliance alone. 

Failure to comply with the above implies personal 

responsibility and invalidates the warranty.
• Installation regulations: 
“Julius” water heaters cannot be installed:

- in bedrooms or bathrooms; 
-  in areas with a risk of fire (for example: garages) 

- this provision also applies for flue ducts;

- on the vertical projection of hobs; 
- in places/environments that constitute com-

mon parts of office condominiums such as 

stairs, cellars, entrance halls, attics, lofts, escape 

routes, etc. if they are not located inside techni-

cal compartments under the responsibility of 

each individual building and only accessible 

to the user (for the features of the technical 

compartments, see the technical standards in 

force). 

Moreover, open chamber water heaters must 

not be installed in places where commercial, 

artisan or industrial activities take place, which 

use products that may develop volatile vapours 

or substances (e.g. acid vapours, glues, paints, 

solvents, combustibles, etc.), as well as dusts (e.g. 

dust deriving from the working of wood, coal 

fines, cement, etc.). These may be damaging for 

the components of the appliance and jeopardise 

functioning. 

It is also appropriate that they are not installed in 

places where  wood-burning heat generators are 

present (open fires), which are not sealed with 

respect to the installation environment.

Attention:

 wall mounting of the water heater 

must guarantee stable and efficient support for 

the generator

The plugs (standard supply) are to be used only in 

conjunction with the mounting brackets or fixing 

template to fix the water heater to the wall;

 they 

only ensure adequate support if inserted correctly 

(according to technical standards) in walls made 

of solid or semi-hollow brick or block. In the 

case of walls made from hollow brick or block, 

partitions with limited static properties, or in any 

case walls other than those indicated, a static test 

must be carried out to ensure adequate support.

N.B.: the hex head screws supplied in the blister 

pack are to be used exclusively to fix the relative 

mounting bracket to the wall.

These appliances are used to heat water to below 

boiling temperature in atmospheric pressure.

They must be connected to a DHW distribution 

network suited to their performance and power. 

They must also be installed in an environment 

in which the temperature cannot fall below 0°C. 

They must not be exposed to atmospheric agents.

YES

NO

Summary of Contents for JULIUS 11 4 ERP

Page 1: ...JULIUS 11 4 ERP JULIUS 14 4 ERP EN Instruction and recommendation booklet 1 038493ENG ...

Page 2: ......

Page 3: ...in compliance with the regulations in force according to the manufacturer s instructions and by an authorised company which has specific technical expertise in the system sector as required by Law Improper installation or assembly of the Immergas appliance and or components accessories kit and devices can cause unexpected problems to people animals and objects Read the instructions provided with t...

Page 4: ...ription of the anomalies 10 2 7 Switching off the water heater 10 2 8 Replacing the batteries 10 2 9 Emptying the water heater 10 2 10 Protection against freezing 10 2 11 Case cleaning 10 2 12 Decommissioning 10 3 Checks and maintenance 11 3 1 Hydraulic diagram 11 3 2 Wiring diagram 12 3 3 Troubleshooting 12 3 4 Converting the water heater to other types of gas 12 3 5 Possible adjustments 12 3 6 Y...

Page 5: ...r incorrect operation turn the appliance off and contact an authorised company e g the Authorised Tech nical Assistance centre which has specifically trained staff and original spare parts Do not attempt to modify or repair the appliance alone Failuretocomplywiththeaboveimpliespersonal responsibility and invalidates the warranty Installation regulations Julius water heaters cannot be installed in ...

Page 6: ...the water heater Water connec tions must be made in a rational way following the set up of the water heater couplings on the Attention to preserve the duration and the ef ficiency features of the appliance in the presence of water whose features can lead to the deposit of scale installation of the polyphosphate dispenser kit is recommended 1 5 ELECTRIC POWER SUPPLY This water heater is powered by ...

Page 7: ...e case of repeated interventions of the fumes exhaust control device check the fumes exhaust flue and the ventilation of the room in which the water heater is located 1 9 GAS SYSTEM START UP To start up the system refer to the technical standard in force This divides the systems and therefore the start up operations into three categories new systems modified systems re activated systems In particu...

Page 8: ... 4 Ignition electrode 5 Ignition and flame control P C B 6 battery compartment 7 Connection pipe pressure point 8 Chimney safety thermostat 9 Overheating safety thermostat 10 Valve burner pipe pressure point 11 Gas selector 12 Temperature selector switch 13 DHW heat exchanger 14 Combustion chamber 15 Burner 16 Water gas valve ...

Page 9: ...at can put the room into de pression at the same time as the water heater un less there are additional openings dimensioned in a way to satisfy the further necessity for air For the dimensioning of these additional open ings refer to qualified technical staff and to current technical Attention using any components that use electrical power requires some fundamental rules to be observed never pull ...

Page 10: ...r to the hydraulic connections To replace the bat teries open the relevant compartment by pulling the lid down and removing the batteries present Insert the new batteries respecting the polarities indicated on the internal wall of the lid itself N B only use new LR20 1 5V alkaline batter ies Dispose of the batteries replaced according to the indications supplied by the manufacturer Do not use re c...

Page 11: ...1 Overheating safety thermostat 2 Valve burner pipe pressure point 3 Valve intake diaphragm 4 Connection pipe pressure point 5 Chimney safety thermostat 6 Fumes hood 7 DHW heat exchanger 8 Pilot group 9 Burner 10 Water gas valve AC Domestic hot water outlet AF Domestic cold water inlet G Gas supply ...

Page 12: ... CONVERTING THE WATER HEATER TO OTHER TYPES OF GAS If the appliance has to be converted to a differ ent gas type to that specified on the data plate request the relative conversion kit for quick and easy conversion The gas conversion operation must be carried out by an authorised company e g Authorised Technical After Sales Service 3 5 POSSIBLE ADJUSTMENTS Regulation of the water heater heat outpu...

Page 13: ...casing can be completely removed as follows 1 Loosen the lower screws a that fix the lower protection grid b and the casing c 2 Release the casing c from the lower brackets d pulling the sides slightly outwards 3 Pull the casing towards you in the lower side 4 Push the casing upwards in a way to be able to extract it from the upper hooks e ...

Page 14: ...89 3 8 5 7310 1 04 1 80 18 4 0 78 5 60 57 1 0 76 7 04 71 8 7 8 6708 0 95 1 40 14 3 0 71 4 70 47 9 0 70 5 90 60 2 METHANE G20 BUTANE G30 PROPANE G31 THERMAL POWER THERMAL POWER BURNER GAS FLOW RATE PRESS BURNER NOZZLES BURNER GAS FLOW RATE PRESS BURNER NOZZLES BURNER GAS FLOW RATE PRESS BURNER NOZZLES kW kcal h m3 h mbar mm H2 O kg h mbar mm H2 O kg h mbar mm H2 O 24 4 20984 2 89 11 30 115 2 2 15 2...

Page 15: ...at Q Nom Min mg kWh 205 135 270 149 235 142 Flue temperature at nominal output C 183 189 184 Flue temperature at minimum output C 126 130 126 Julius 14 4 ErP Gas nozzle diameter mm 1 35 0 80 0 80 supply pressure mbar mm H2 O 20 204 29 296 37 377 Pilot nozzle diameter mm 0 26 0 22 0 22 Gas cone seats mm 9 0 9 0 9 0 Gas cone inlet code 0855 0881 0881 Gas cone outlet code 0863 0884 0884 Gas inlet val...

Page 16: ... temperature of 15 C The data relevant to domestic hot water per formance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15 C the values are measured directly at the water heater outlet considering that to obtain the data declared mixing with cold water is necessary The max sound level emitted during water heater operation is 55 dBA The sound level value is referred to semi...

Page 17: ...uel consumption for the domestic hot water function AFC 7 GJ Water heating energy efficiency ηwh 66 Parameter value Annual fuel consumption for the domestic hot water function AFC 12 GJ Water heating energy efficiency ηwh 76 For proper installation of the appliance refer to chapter 1 of this booklet for the installer and current installation regulations For proper maintenancerefertochapter3ofthisb...

Page 18: ...lect the actual energy efficiency after installation since such efficiency is affected by additional factors such as the heat loss in the distribution system and the size of the products compared to the size and features of the building Facsimile for filling in domestic hot water production system package fiche 3 13 PARAMETERS FOR FILLING IN THE PACKAGE FICHE Should you wish to install an assembly...

Page 19: ...4 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy efficiency of the set of products indicated in this sheet may not reflect the actual energy efficiency after installation since such efficiency is affected by additional factors such as the heat loss in the distribution system and the size of the products compared to the size a...

Page 20: ...immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038493ENG rev ST 002036 000 09 15 Inglese per IRLANDA IE ...

Reviews: