2.12 CASE CLEANING.
Use damp cloths and neutral detergent to clean
the boiler casing. Never use abrasive or powder
detergents.
2.13 DECOMMISSIONING.
In the event of permanent shutdown of the boiler,
contact professional staff for the procedures and
ensure that the electrical, water and gas supply
lines are shut off and disconnected.
2.14 PARAMETERS AND INFORMATION
MENU.
By pressing the button "D" it is possible to access
a menu divided into three main parts:
- “M1” information
- “M3” customisations
- “M5” configurations: menu reserved to the
technician and for which a password is required
(See “Maintenance” chapter).
- “M9” settings.
By turning the central heating temperature se-
lector switch (3) scroll through the menu items.
By pressing button “D” access the various levels
of the menu and the choice of parameters is
confirmed. Press button “C” to go back one level.
Key:
1 - Gas cock
2 - Cold water inlet cock
3 - System filling valve
1st
Level
Button
2nd Level
Button
3rd Level
Button
Description
M1
D
C
P11
D
C
View the management software version of the P.C.B. installed in the
boiler
P12
View the total functioning hours of the boiler
P13
View the number of burner ignitions
P14
(with optional
external probe
present)
- - -
(without external
probe (optional)
D
C
P14/A
View the current external temperature (if optional external probe
present)
P14/B
View the minimum external temperature recorded (if optional exter-
nal probe present)
P14/C
View the maximum external temperature recorded (if optional exter-
nal probe present)
D
x
select
C
By pressing button "D" the MIN and MAX temperatures measured are
reset to zero
P15
D
C
RESET
No display on this boiler model
P17
View the speed in instantaneous revs.of the fan
P18
View the circulator pump instantaneous speed (in %)
P19
View the last 5 events that caused boiler shutdown. Indicator (6)
shows the sequential number from 1 to 5 and on indicator (7) the
relative error code.
By pressing button "D" repeatedly it is possible to view the function-
ing time and the number of ignitions at which the anomaly occurred
“M1” information menu.
This menu contains the various information relative to boiler functioning: