32
STEEkW ed 12/03 EOLO Eco kW
Technical Documentation
Technical Documentation
EOLO Eco 24 kW variable heat output.
EOLO Eco 28 kW variable heat output.
NATURAL GAS (G20)
PROPANE (G31)
HEAT
OUTPUT
HEAT
OUTPUT
GAS FLOW
RATE
BURNER
NOZZLE PRESS.
BURNER
GAS FLOW
RATE
BURNER
NOZZLE PRESS.
BURNER
(kW)
(kcal/h)
(m
3
/h)
(mbar)
(mm H
2
O)
(kg/h)
(mbar)
(mm H
2
O)
24.0
20640
2.73
13.1
134
2.01
35.61
363
23.3
20000
2.65
12.3
125
1.94
33.46
341
22.1
19000
2.52
11.1
113
1.85
30.26
309
20.9
18000
2.38
9.9
101
1.75
27.26
278
19.8
17000
2.25
8.8
90
1.65
24.43
249
18.6
16000
2.13
7.8
79
1.56
21.77
222
17.4
15000
2.00
6.8
70
1.47
19.27
197
16.3
14000
1.87
5.9
60
1.37
16.93
173
15.1
13000
1.74
5.1
52
1.28
14.74
150
14.0
12000
1.62
4.3
44
1.19
12.69
129
12.8
11000
1.49
3.6
36
1.09
10.78
110
12.2
10500
1.43
3.2
33
1.05
9.88
101
11.6
10000
1.36
2.9
30
1.00
9.01
92
11.0
9500
1.30
2.6
26
0.95
8.18
83
10.5
9000
1.23
2.3
23
0.91
7.38
75
9.3
8000
1.10
1.7
17
0.81
5.88
60
NATURAL GAS (G20)
PROPANE (G31)
HEAT
OUTPUT
HEAT
OUTPUT
GAS FLOW
RATE
BURNER
NOZZLE PRESS.
BURNER
GAS FLOW
RATE
BURNER
NOZZLE PRESS.
BURNER
(kW)
(kcal/h)
(m
3
/h)
(mbar)
(mm H
2
O)
(kg/h)
(mbar)
(mm H
2
O)
28.0
24080
3.19
12.81
131
2.34
36.62
374
27.9
24000
3.18
12.72
130
2.33
36.33
371
26.7
23000
3.05
11.69
119
2.24
32.81
335
25.6
22000
2.92
10.71
109
2.14
29.52
301
24.4
21000
2.79
9.76
100
2.05
26.43
270
23.3
20000
2.66
8.86
90
1.95
23.56
240
22.1
19000
2.53
8.00
82
1.86
20.90
213
20.9
18000
2.40
7.18
73
1.76
18.44
188
19.8
17000
2.27
6.39
65
1.67
16.18
165
18.6
16000
2.15
5.64
58
1.58
14.11
144
17.4
15000
2.02
4.93
50
1.48
12.24
125
16.3
14000
1.89
4.26
43
1.39
10.56
108
15.1
13000
1.76
3.62
37
1.29
9.08
93
14.0
12000
1.63
3.01
31
1.20
7.80
80
12.8
11000
1.50
2.44
25
1.10
6.70
68
10.5
9000
1.24
1.41
14
0.91
5.12
52