1.9 CONCENTRIC HORIZONTAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Installation of this terminal is governed by cur-
rent technical regulations.
This terminal is connected directly to the outside
of the building for air intake and flue exhaust. The
horizontal kit can be installed with the rear, right
side, left side or front outlet.
• External grid. The Ø 60/100 intake/exhaust
terminal, if properly installed, is pleasant to
look at on the outside of the building. Make
sure that the external silicone wall sealing plate
is properly inserted in the wall.
Horizontal intake-exhaust kit Ø 60/100.
Kit
assembly
(Fig. 8)
: install the bend with flange
(2) onto the central hole of the water heater
inserting the gasket (1) and tighten using the
screws included in the kit. Couple the concentric
terminal pipe Ø 60/100 (3) with the male end
(smooth) into the female end (with lip seals)
of the bend (2) up to the stop, making sure that
the internal and external wall sealing plate have
been fitted, this will ensure sealing and joining
of the kit elements.
• Extensions for Ø 60/100 horizontal kit
(Fig. 9)
.
The kit with this configuration can be extended
up to a
max. horizontal length of 3.2 m
includ-
ing the terminal with grid and excluding the
concentric bend leaving the water heater. In this
case the special extensions must be requested.
The kit includes:
N° 1 - Gasket (1)
N° 1 - Concentric bend Ø 60/100 (2)
N° 1 - Int./exhaust concentric terminal Ø 60/100 (3)
N° 1 - Internal wall sealing plate (4)
N° 1 - External wall sealing plate (5)
1.10 CONCENTRIC VERTICAL KIT
INSTALLATION.
Type C configuration, sealed chamber and
fan assisted.
Concentric vertical intake and exhaust kit. This
vertical terminal is connected directly to the out-
side of the building for air intake and flue exhaust.
N.B.:
the vertical kit with aluminium tile enables
installation on terraces and roofs with a maxi-
mum slope of 45% (approx 25°) and the height
between the terminal cap and half-shell (374
mm) must always be respected.
Vertical kit with aluminium tile Ø 60/100.
To use this kit one must use the fixing plate kit
60/100 (sold separately).
Kit assembly
(Fig. 10)
: install the concentric
flange (2) on the central hole of the water heater
inserting the gasket (1) and tighten using the
screws in the kit. Fit the male end (smooth) of the
adapter (3) into the female end of the concentric
flange (2). Imitation aluminium tile installation.
Replace the tile with the aluminium sheet (5),
shaping it to ensure that rainwater runs off.
Position the fixed half-shell (7) and insert the in-
take-exhaust pipe (6). Fit the Ø 80/125 concentric
terminal pipe with the male end (6) (smooth) to
the female end of the adapter (3) (with lip gasket)
up to the stop; making sure that the wall sealing
plate (4) has been fitted, this will ensure sealing
and joining of the elements making up the kit.
• Extensions for vertical kit Ø 60/100
(Fig. 11
).
The kit with this configuration can be extend-
ed to a
max. straight vertical length of 4.2 m
,
including the terminal. This configuration
corresponds to a resistance factor of 100. In
this case specific extensions must be requested.
The fixing plate kit includes:
N° 1 - Gasket (1)
N° 1 - Female concentric
flange (2)
The Kit includes:
N° 1 - Concentric intake-
exhaust pipe
Ø 60/100 (3)
N° 1 - Wall sealing plate (4)
N° 1 - Aluminium tile (5)
N° 1 - Fixed half-shell (6)
N° 1 - Mobile half-shell (7)
N.B.:
to calculate the equivalent lengths, refer to the table on page 8.
MAXIMUM EQUIVALENT LENGTH 3200
MAXIMU
M EQ
UIV
ALENT LEN
GTH 4200
N.B.:
to calculate the equivalent lengths,
refer to the table on page 8.
M