3.10 COMBUSTION PARAMETERS.
3.11 TECHNICAL DATA.
G20
G30
G31
Supply pressure
mbar
20
28-30
37
Caesar Eco 11
Diameter of the main burner nozzle (No. of nozzles) (*)
mm
0,86 (18) + 0,83 (4)
0,50 (18) + 0,48 (4)
0,50 (18) + 0,48 (4)
Nozzles (*)
N.
22
22
22
P.C.I. (15° C 1013 mbar)
MJ/m
3
34,02
116,09
88
WI (15° C 1013 mbar)
MJ/m
3
45,67
80,58
70,69
Consumption
m
3
/h
2,28
-
-
kg/h
-
1,70
1,67
Max./min. burner pressure
mbar
11,70 - 2,60
28,30 - 6,10
36,40 - 8,00
Min./max. flue flow rate at max heat output
kg/h
39,308 - 60,035
42,465 - 57,527
43,379 - 49,379
Flue temperature at min./max. output
°C
101 - 160
101 - 165
96 - 159
Emissions of nitrogen oxides (NOx)
mg/kWh
35,00
60,00
45,00
Air flow rate
Nm
3
/h
46,315
44,359
37,911
Caesar Eco 14
Diameter of the main burner nozzle (No. of nozzles) (*)
mm
0,86 (24) + 0,83 (4)
0,50 (24) + 0,48 (4)
0,50 (24) + 0,48 (4)
Nozzles (*)
N.
28
28
28
P.C.I. (15° C 1013 mbar)
MJ/m
3
34,02
116,09
88
WI (15° C 1013 mbar)
MJ/m
3
45,67
80,58
70,69
Consumption
m
3
/h
2,86
-
-
kg/h
-
2,13
2,10
Max./min. burner pressure
mbar
12,40 - 2,00
28,20 - 4,40
36,00 - 5,60
Min./max. flue flow rate at max heat output
kg/h
40,233 - 66,526
45,936 - 73,412
38,273 - 62,873
Flue temperature at min./max. output
°C
90 - 177
95 - 177
91 - 174
Emissions of nitrogen oxides (NOx)
mg/kWh
29,00
45,00
21,00
Air flow rate
Nm
3
/h
51,262
56,620
48,280
Caesar Eco 11
Caesar Eco 14
Nominal heat input (Qn)
kW (kcal/h)
21,5 (18490)
27,0 (23220)
Minimum heat input (Qm)
kW (kcal/h)
9,5 (8170)
10,0 (8600)
Nominal heat output (useful) (Pn)
kW (kcal/h)
19,3 (16600)
24,3 (20900)
Minimum heat output (useful) (Pm)
kW (kcal/h)
8,6 (7400)
9,0 (7740)
Domestic hot water flow limiter
l/min
8
10
Flow rate capacity in continuous duty (∆T 35°C)
l/min
8
10
Minimum water flow rate ignition
l/min
2
2
Domestic hot water adjustable temperature
°C
37 - 60
37 - 60
Minimum water pressure
bar
0,13
0,13
Maximum water pressure
bar
10
10
Water heater weight
kg
14
16
Fan residual head without pipes
Pa
72
90
Electrical connection
V/Hz
230/50
230/50
Installed electric power
W
41
59
Equipment electrical system protection
-
IPX5D
IPX5D
Type of appliance
B22 / B22P / B32 / C12 / C12x / C32 / C32x / C42 / C42x /
C52 / C52x / C62 / C62x / C82 / C82x
Category
II2R3R
(*): it is strictly forbidden to replace the nozzles individually. If necessary, replace the entire manifold.
- The data relevant to domestic hot water per-
formance refer to a dynamic inlet pressure of 2
bar and an inlet temperature of 15°C; the values
are measured directly at the water heater outlet
considering that to obtain the data declared
mixing with cold water is necessary.