Our policy is one of continued research and development. We therefore reserve the right to amend, 

without notice, the specifications given in this document. (1999-xxxxb) © 2020 IMI International s.r.o.

05/21

IM/en 8.240.115.001

Technical Data

Fluid: Compressed air

Metal bowl: 17 bar (250 psig)

Transparent bowl: 10 bar (150 psig

Operating temperature*: 

Metal bowl: –20° ... +65°C (0° ... +150°F) 

Transparent bowl: –20° ... +50°C (0° ... +125°F)

* Air supply must be dry enough to avoid ice  forma-
tion at temperatures below +2°C (+35°F).

Integral F64B/L Pre-filter Element: 40 µm 

nominal 

Particle Removal F64B/L: 0,01 µm

Maximum Remaining Oil Content:

0,003 mg/m3 at +21°C (+70°F)

Air Quality: Within ISO8573-1:2010:  1:7:0

 Typical performance characteristics

Inlet pressure

(bar)

 Maximum flow (dm

3

/s) *

F64B 

           F64L

6,7

7,1

10,7

11,3

13,8

14,4

6,3 

15,6

16,3

16,5

17,2

18,8

19,5

* Maximum flow to maintain stated oil removal 

performance.

Automatic drain connection: 1/8”

Automatic drain operating conditions: 

Bowl pressure required to close drain: 

Greater than 0,3 bar (5 psig)

Bowl pressure required to open drain: 

Less than 0,2 bar (3 psig)

Minimum air flow required to close drain: 

1 dm3/s (2 scfm) 

Manual operation: Depress pin inside drain 

outlet to drain bowl

Nominal bowl size: 0,2 litre (7 fluid oz) 

Materials:

Body: Zinc 

Bowl: 

Metal: Zinc

Transparent: Polycarbonate 

Metal bowl sight glass, standard: Pyrex 

Element: Composite materials 

Elastomers: Synthetic rubber

Replacement Items

Service Kit 

(Item No. (s) 3, 5, 8, 9, 14, 16, 17, 18, 20):

F64B-  

F64B-KITA0V

F64L- F64L-KITA0V

Pyrex sight glass kit (Item No. 7) 

2273-97

Element, coalescing (Item No. 3):

F64B  

5350-99

F64L  

5350-98

Element, integral pre-filter 

(Item No. 16) 

3698-02

Activated carbon pack

(Item No. 18) 

5568-02

Manual drain (Item No. 9, 12, 13, 14)  684-84

Automatic drain (Item No. 8) 

  6000-70

Automatic drain - USA only

(Item No. 8) 

  3000-70

Operation

On exceptionally dirty lines it may be neces-

sary to clean the pre-filter element at 90 day 

intervals.

Do not exceed Maximum Flow rating or 

excessive pressure drop will result or oil carry 

over may occur.

The top filter element acts as absorbant 

pack to remove any small traces of oil or 

hydro-carbon gases which might

be carried over from the lower bowl. 

These elements also provide protection in the 

event of any failure of the lower filter.

Resistance to air flow will gradually increase 

as the filter element collects solid particles. 

The pressure differential across the element 

should not be allowed to exceed 0,7 bar

(10 psi) or damage to the element may 

occur.

Servicing

Air Service equipment should be initially 

maintained annually. Use, quality of air and 

condition at examination may indicate ad-

justment of the maintenance interval.

1. Open manual drain to expel accumulated  

  liquids. Keep liquids below element (3).

2. To operate automatic drain manually, lift  

  operating pin in bottom outlet with a blunt  

 rod.

3. Clean or replace filter element when dirty.

Option selector

 Port

2 1/4“

3 3/8“

4 1/2“

6 3/4“

N  No yoke

 Drain

A Automatic

M Manual

 Bowl

R  Metal with Pyrex sight glass

T Transparent

 Thread

 A 

PTF

ISO Rc tapered

G  ISO G parallel

No yoke

F64

˙

 – 

˙˙N

 – 

˙˙0

 Bowl

B   Coalescing & 

 

activated carbon element

Extended coalescing & 

 

activated carbon element

8

9

18

18

21

15

15

17

20

16

19
3

3

1

1

10

9

10

5

5

12
14

13

14

20

16

6

19
3

3

9

5

12
14

10

13

10

8

9

5

14

4

14

21

28

37

17

4

2

2

7

7

F64B, F64L - Ultra High Efficiency Coalescing Filter

 Installation & Maintenance Instructions

Reviews: