background image

  

INDUSTRIAL MONITORING INSTRUMENTATION DIVISION

 

PAGE  

 

3

SENSO

RS AN

D INS

TRUME

N

TATIO

N F

OR MAC

HINE 

CON

DITION M

ONIT

ORIN

G

 

 

introduction 

 

The Models 691B41 and 691B42 are vibration switch boxes that provide terminal strip input with the convenience 

of BNC outputs.  They are used in conjunction with commercially available data collectors and analyzers.  They 

provide inputs and switched outputs for vibration sensors with built in temperature sensors.  A few specifications 

are listed below for easy reference: 

 

 

Model Number 

Number of Channels 

 

691B41 .............................................................................................................................................

6

 

 

691B42 ...........................................................................................................................................

12

 

 

Input Connectors ........................................................................................

4-Socket Terminal Strip

 

 

Output Connector:  Vibration.............................................................................................

BNC Jack 

 

Output Connector:  Temperature ......................................................................................

BNC Jack

 

 

Enclosure Type .......................................................................................................

NEMA 4X (IP67)

 

 

Size..............................................................................................

8 x 6 x 4 in [203 x 152 x 102 mm] 

 
 

installation 

 

Establish an easily accessible location for installation and keep in mind that the cabling will be coming from the 

bottom panel of the enclosure.  Make the necessary holes in the panel for the vibration sensor cabling.  Use the 

supplied mounting feet to install the enclosure. 

 

NOTE:

  Be very careful when punching and/or drilling the enclosure as to not damage the internal metal, terminal 

strips and printed circuit boards. 

 

Summary of Contents for 691B41

Page 1: ...Box Installation and Operating Manual For assistance with the operation of this product contact the IMI Sensors Division of PCB Piezotronics Inc Division toll free 24 hour SensorLine Fax 716 684 3823...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...c ch h B Bo ox x M Mo od de el l 6 69 91 1B B4 42 2 S Sw wi it tc ch h B Bo ox x Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax...

Page 5: ...N MONITORING table of contents Introduction page 3 Installation page 3 Terminal Strip Wiring page 4 Grounding the Enclosure page 5 figure 1 vibration switch box page 5 Calibration page 5 ESD Warning I...

Page 6: ...or easy reference Model Number Number of Channels 691B41 6 691B42 12 Input Connectors 4 Socket Terminal Strip Output Connector Vibration BNC Jack Output Connector Temperature BNC Jack Enclosure Type N...

Page 7: ...erminal strip wiring Positive Input Connect the sensor s positive input Negative Input Connect the sensor s negative input Shield Connect the sensor s shield if applicable TEMP SH TEMP Temperature Sen...

Page 8: ...cted To do this the bottom right inner mounting hole has a double nut included Unscrew the nut and insert ground wire between the washers and screw nut tightly down again This will earth ground all th...

Page 9: ...voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on...

Page 10: ...ion will be provided prior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected wi...

Page 11: ...o have your purchase price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days...

Page 12: ......

Page 13: ......

Reviews: