INDUSTRIAL MONITORING INSTRUMENTATION DIVISION
PAGE
3
SENSO
RS AN
D INS
TRUME
N
TATIO
N F
OR MAC
HINE
CON
DITION M
ONIT
ORIN
G
introduction
The Models 691B41 and 691B42 are vibration switch boxes that provide terminal strip input with the convenience
of BNC outputs. They are used in conjunction with commercially available data collectors and analyzers. They
provide inputs and switched outputs for vibration sensors with built in temperature sensors. A few specifications
are listed below for easy reference:
Model Number
Number of Channels
691B41 .............................................................................................................................................
6
691B42 ...........................................................................................................................................
12
Input Connectors ........................................................................................
4-Socket Terminal Strip
Output Connector: Vibration.............................................................................................
BNC Jack
Output Connector: Temperature ......................................................................................
BNC Jack
Enclosure Type .......................................................................................................
NEMA 4X (IP67)
Size..............................................................................................
8 x 6 x 4 in [203 x 152 x 102 mm]
installation
Establish an easily accessible location for installation and keep in mind that the cabling will be coming from the
bottom panel of the enclosure. Make the necessary holes in the panel for the vibration sensor cabling. Use the
supplied mounting feet to install the enclosure.
NOTE:
Be very careful when punching and/or drilling the enclosure as to not damage the internal metal, terminal
strips and printed circuit boards.