background image

list(s)  accompanying  the  shipment.  A 
detailed  account  of  the  nature  of  the 
problem(s)  being  experienced  with  the 
equipment  should  also  be  included 
inside  the  package(s)  containing  any 
returned materials.   
 
A  Purchase  Order,  included  with  the 
returned  materials,  will  expedite  the 
turn-around  of  serviced  equipment.  It  is 
recommended  to  include  authorization 
on  the  Purchase  Order  for  PCB  to 
proceed  with  any  repairs,  as  long  as 
they  do  not  exceed  50%  of  the 
replacement  cost  of  the  returned 
item(s).  PCB  will  provide  a  price 
quotation 

or 

replacement 

recommendation  for  any  item  whose 
repair  costs  would  exceed  50%  of 
replacement cost, or any item that is not 
economically  feasible  to  repair.  For 
routine 

calibration 

services, 

the 

Purchase 

Order 

should 

include 

authorization  to  proceed  and  return  at 
current  pricing,  which  can  be  obtained 
from 

factory 

customer 

service 

representative.   
 

Contact  Information 

–  International 

customers  should  direct  all  inquiries  to 
their  local  distributor  or  sales  office.  A 

complete  list  of  distributors  and  offices 
can 

be 

found 

at 

www.pcb.com. 

Customers within the United States may 
contact  their  local  sales  representative 
or 

factory 

customer 

service 

representative.  A  complete  list  of  sales 
representatives 

can 

be 

found 

at 

www.pcb.com. 

Toll-free 

telephone 

numbers  for  a  factory  customer  service 
representative, 

in 

the 

division 

responsible  for  this  product,  can  be 
found on the title page at the front of this 
manual.  Our  ship  to  address  and 
general contact numbers are:   
 
PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840  
24-hour SensorLine

SM

: (716) 684-0001  

Website: www.pcb.com 

E-mail: [email protected]  
 
 
 
 
 
 
 
 

Summary of Contents for 682B05

Page 1: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 2: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 3: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 4: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 5: ...ING Model 682B05 Bearing Fault Detector Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IM...

Page 6: ...CONDITION MONITORING Table of Contents Introduction Page 3 General Features Installation and Wiring Page 4 Configuring the 682B05 Page 8 ESD Sensitivity Page 10 Warranty Servicing Warranty Service Ret...

Page 7: ...al Features Early detection of high frequency impact faults related to bearing failure and lube starvation External transmitters signal conditioners and ICP power supplies can be eliminated by direct...

Page 8: ...l 682B05 is designed to be mounted on a 35mm Din Rail Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils IMI Sensors recommends mounting the 682B05 in a type NEM...

Page 9: ...osure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devices...

Page 10: ...12 and BNC Jack Pin 9 RV Pin 10 RV Pin 11 No Connection Pin 12 No Connection 4 to 20mA Fault Detector Output Pins 13 14 Pin 13 4 to 20mA Fault Output Pin 14 4 to 20mA Fault Output 4 to 20mA Overall Vi...

Page 11: ...UMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram Note If using the 682A01 mount the 682B05 to the left side of the power supply as shown with a recommended minimum separation distanc...

Page 12: ...s The switches are used to configure the 682B05 for various sensor and vibration ranges The PC Board is accessible through the front of the conditioner by removing the Screw Terminal Connectors and di...

Page 13: ...N 20g Peak UP DOWN OFF OFF ON 0 5 in sec RMS DOWN UP ON OFF OFF 0 5 in sec Peak DOWN DOWN ON OFF OFF 1 0 in sec RMS DOWN UP OFF ON OFF 1 0 in sec Peak DOWN DOWN OFF ON OFF 2 0 in sec RMS DOWN UP OFF O...

Page 14: ...nt may be impaired if the equipment is used in a manner not specified by PCB Piezotronics Inc Caution 1 ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can dama...

Page 15: ...oid any warranty If factory service is required return the instrumentation according to the Return Procedure stated below A repair and or replacement quotation will be provided prior to servicing at n...

Page 16: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Page 17: ......