background image

 

 

 

The information contained in this document supersedes all similar information that 
may be found elsewhere in this manual. 

  

 

 

Service 

–  Due  to  the  sophisticated 

nature  of  the  sensors  and  associated 
instrumentation 

provided 

by 

PCB 

Piezotronics,  user  servicing  or  repair  is 
not  recommended  and,  if  attempted, 
may  void  the  factory  warranty.  Routine 
maintenance,  such  as  the  cleaning  of 
electrical  connectors,  housings,  and 
mounting  surfaces  with  solutions  and 
techniques  that  will  not  harm  the 
physical  material  of  construction,  is 
acceptable. Caution should be observed 
to  ensure  that  liquids  are  not  permitted 
to  migrate  into  devices  that  are  not 
hermetically 

sealed. 

Such 

devices 

should  only  be  wiped  with  a  dampened 
cloth  and  never  submerged  or  have 
liquids poured upon them.   
 

Repair 

–  In  the  event  that  equipment 

becomes 

damaged 

or 

ceases 

to 

operate,  arrangements  should  be  made 
to  return  the  equipment  to  PCB 
Piezotronics for repair. User servicing or 
repair  is  not  recommended  and,  if 
attempted, 

may 

void 

the 

factory 

warranty.     
 

Calibration 

–  Routine  calibration  of 

sensors  and  associated  instrumentation 
is  recommended  as  this  helps  build 
confidence  in  measurement  accuracy 
and 

acquired 

data. 

Equipment 

calibration 

cycles 

are 

typically 

established  by  the  users  own  quality 
regimen.  When  in  doubt  about  a 
calibration cycle, a good 

“rule of thumb” 

is to recalibrate on an annual basis. It is 

also  good  practice  to  recalibrate  after 
exposure  to  any  severe  temperature 
extreme, 

shock, 

load, 

or 

other 

environmental  influence,  or  prior  to  any 
critical test.  
 
PCB  Piezotronics  maintains  an  ISO- 
9001  certified  metrology  laboratory  and 
offers  calibration  services,  which  are 
accredited  by  A2LA  to  ISO/IEC  17025, 
with  full  traceability  to  SI  through 
N.I.S.T.  In  addition  to  the  normally 
supplied  calibration,  special  testing  is 
also  available,  such  as:  sensitivity  at 
elevated  or  cryogenic  temperatures, 
phase  response,  extended  high  or  low 
frequency  response,  extended  range, 
leak 

testing, 

hydrostatic 

pressure 

testing,  and  others.  For  information  on 
standard 

recalibration 

services 

or 

special  testing,  contact  your  local  PCB 
Piezotronics 

distributor, 

sales 

representative,  or  factory  customer 
service representative.   
 

Returning  Equipment 

– 

Following 

these  procedures  will  ensure  that  your 
returned  materials  are  handled  in  the 
most 

expedient 

manner

Before 

returning 

any 

equipment 

to 

PCB 

Piezotronics, 

contact 

your 

local 

distributor,  sales  representative,  or 
factory  customer  service  representative 
to  obtain  a  Return 

Warranty,  Service, 

Repair,  and  Return  Policies  and 
Instructions 

Materials  Authorization 

(RMA)  Number.  This  RMA  number 
should be clearly marked on the outside 
of  all  package(s)  and  on  the  packing 

Service, Repair, and Return 
Policies and Instructions 

Summary of Contents for 682B05

Page 1: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 2: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 3: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 4: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 5: ...ING Model 682B05 Bearing Fault Detector Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IM...

Page 6: ...CONDITION MONITORING Table of Contents Introduction Page 3 General Features Installation and Wiring Page 4 Configuring the 682B05 Page 8 ESD Sensitivity Page 10 Warranty Servicing Warranty Service Ret...

Page 7: ...al Features Early detection of high frequency impact faults related to bearing failure and lube starvation External transmitters signal conditioners and ICP power supplies can be eliminated by direct...

Page 8: ...l 682B05 is designed to be mounted on a 35mm Din Rail Do not install in a harsh area where it can be exposed to cleaning fluids or machine oils IMI Sensors recommends mounting the 682B05 in a type NEM...

Page 9: ...osure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devices...

Page 10: ...12 and BNC Jack Pin 9 RV Pin 10 RV Pin 11 No Connection Pin 12 No Connection 4 to 20mA Fault Detector Output Pins 13 14 Pin 13 4 to 20mA Fault Output Pin 14 4 to 20mA Fault Output 4 to 20mA Overall Vi...

Page 11: ...UMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram Note If using the 682A01 mount the 682B05 to the left side of the power supply as shown with a recommended minimum separation distanc...

Page 12: ...s The switches are used to configure the 682B05 for various sensor and vibration ranges The PC Board is accessible through the front of the conditioner by removing the Screw Terminal Connectors and di...

Page 13: ...N 20g Peak UP DOWN OFF OFF ON 0 5 in sec RMS DOWN UP ON OFF OFF 0 5 in sec Peak DOWN DOWN ON OFF OFF 1 0 in sec RMS DOWN UP OFF ON OFF 1 0 in sec Peak DOWN DOWN OFF ON OFF 2 0 in sec RMS DOWN UP OFF O...

Page 14: ...nt may be impaired if the equipment is used in a manner not specified by PCB Piezotronics Inc Caution 1 ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can dama...

Page 15: ...oid any warranty If factory service is required return the instrumentation according to the Return Procedure stated below A repair and or replacement quotation will be provided prior to servicing at n...

Page 16: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Page 17: ......