Repair and Maintenance 

 

 

PCB guarantees Total Customer Satisfaction through its 

“Lifetime  Warranty  Plus”  on all  Platinum  Stock  Products 

sold by PCB and through its limited warranties on all other 
PCB  Stock,  Standard  and  Special  products.  Due  to  the 
sophisticated  nature  of  our  sensors  and  associated 
instrumentation, 

field  servicing  and  repair  is  not 

recommended  and,  if  attempted,  will  void  the  factory 
warranty

 
Beyond  routine  calibration  and  battery  replacements 
where  applicable,  our  products  require  no  user 
maintenance.  Clean  electrical  connectors,  housings,  and 
mounting surfaces with solutions and techniques that will 
not  harm  the  material  of  construction.  Observe  caution 
when using liquids near devices that are not hermetically 
sealed.  Such  devices  should  only  be  wiped  with  a 
dampened cloth

never saturated or submerged.  

 

In the event that equipment becomes damaged or ceases 
to operate, our Application Engineers are here to support 
your  troubleshooting  efforts  24  hours  a  day,  7  days  a 
week. Call or email with model and serial number as well 
as a brief description of the problem. 

 

Calibration 

 

 

Routine 

calibration 

of 

sensors 

and 

associated 

instrumentation  is  necessary  to  maintain  measurement 
accuracy. We recommend calibrating on an annual basis, 
after  exposure  to  any  extreme  environmental  influence, 
or prior to any critical test.  

 

PCB Piezotronics is an ISO-9001 certified company whose 
calibration  services  are  accredited  by  A2LA  to  ISO/IEC 
17025,  with  full  traceability  to  SI  through  N.I.S.T.  In 
addition to our standard calibration services, we also offer 
specialized  tests,  including:  sensitivity  at  elevated  or 
cryogenic  temperatures,  phase  response,  extended  high 
or low frequency response, extended range, leak testing, 
hydrostatic  pressure  testing,  and  others.  For  more 
information,  contact  your  local  PCB  Piezotronics 
distributor,  sales  representative,  or  factory  customer 
service representative.  

 

Returning Equipment 

 

If  factory  repair  is  required,  our  representatives  will 
provide you with a Return Material Authorization (RMA) 
number, which we use to reference any information you 
have  already  provided  and  expedite  the  repair  process. 
This number should be clearly marked on the outside of 
all  returned  package(s)  and  on  any  packing  list(s) 
accompanying the shipment.  

 

Contact Information 

 

 

PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840 
24-hour SensorLine: (716) 684-0001 
General inquiries

[email protected]

 

Repair inquiries

[email protected]

  

 

For a complete list of distributors, global offices and sales 
representatives, visit our website, 

www.pcb.com

 

 

Safety Considerations

 

 

This  product  is  intended  for  use  by  qualified  personnel 
who  recognize  shock  hazards  and  are  familiar  with  the 
precautions required to avoid injury. While our equipment 
is  designed  with  user  safety  in  mind,  the  protection 
provided by the equipment may be impaired if equipment 
is used in a manner not specified by this manual.  

 

Discontinue use and contact our 24-Hour Sensorline if: 

 

 

Assistance is needed to safely operate equipment 

 

Damage is visible or suspected 

 

Equipment fails or malfunctions 

 

For  complete  equipment  ratings,  refer  to  the  enclosed 
specification sheet for your product. 

 

Definition of Terms and Symbols 

 

 

The following symbols may be used in this manual: 

 

 

DANGER 

Indicates an immediate hazardous 
situation, which, if not avoided, may 
result in death or serious injury.

 

 

Summary of Contents for 640B00

Page 1: ...Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...trial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI MANUAL NUMBER 2531...

Page 7: ...n and Wiring Page 5 Standard Wiring Taking Measurements RV Option RVVO Option TO Option Installation Page 9 Direct Adhesive Mount Standard Stud Mount Adhesive Stud Mount Magnetic Mount ESD Sensitivity...

Page 8: ...further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Velocity Allows for continuous vibration m...

Page 9: ...PAGE 4 Dimension Drawing...

Page 10: ...ply to Pin B or Blue Wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter and or load resistor in line w...

Page 11: ...pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 641BX0 641BX1 641BX2 4 00 0 0 ips rms 0 0 ips rms 0 0 ips rms 8 00 0...

Page 12: ...option which integrates the signal to a value of 100 mV IPS 20 Figure 3 RV and RVVO wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV and RVVO negativ...

Page 13: ...e environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4 20mA Vibration Negative GREE...

Page 14: ...e 645 646 series because of the increased frequency response Direct Adhesive Mount Procedure For restrictions of space or for convenience most sensors with the exception of integral stud models can be...

Page 15: ...to properly prepare the machine surface consider using an adhesive mounting pad as a possible alternative Inspect the area checking that there are no burrs or other foreign particles interfering with...

Page 16: ...requency response This method involves attaching a base to the machine surface then securing the snesor to the base This alows for easy removal of the accelerometer STEP 1 Prepare a smooth flat mounti...

Page 17: ...adhere a stell mounting pad to the test surface This provides a smooth and repeatable location for mounting Figure 9 magnet types STEP 1 After choosing the correct magnet type inspect the unit verifyi...

Page 18: ...rical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a rug Any movement through air Th...

Page 19: ...ATION RMA NUMBER Please have information available such as model and serial number Also to insure efficient service provide a written description of the symptoms and problems with the equipment to a l...

Page 20: ...ed In the interest of constant product improvement we reserve the right tochange specifications without notice ICP is a registeredtrademarkof PCB Piezotronics Inc EX Hazardous Area Approval contact fa...

Page 21: ......

Reviews: