18
Operation & Service Manual
Valve islands VM10 EtherNet/IP
07/2018
Construction & Design is subject to change © 2018 Norgren GmbH
6.
Solenoid Object
Object Class:
100d
Instances:
8 stations
1…16
10 stations
1…20
12 stations
1…24
16 stations
1…32
Each solenoid is a separate instance of the Solenoid Object. The allocation between Instance ID
and solenoid is shown in the following table:
Valve 1…4
V04-12
V04-14
V03-12
V03-14
V02-12
V02-14
V01-12
V01-14
Instance ID
8
7
6
5
4
3
2
1
Valve 5…8
V08-12
V08-14
V07-12
V07-14
V06-12
V06-14
V05-12
V05-14
Instance ID
16
15
14
13
12
11
10
9
Valve 12…9
V12-12
V12-14
V11-12
V11-14
V10-12
V10-14
V09-12
V09-14
Instance ID
24
23
22
21
20
19
18
17
Valve 13…16
V16-12
V16-14
V15-12
V15-14
V14-12
V14-14
V13-12
V13-14
Instance ID
32
31
30
29
28
27
26
25
Following table shows all Instance Attributes of the Solenoid Object:
Attr.
ID
Acces
Rule
Name
Data
Type
Description
Schematic of
Values
1
Get/Set
Solenoid Value
Bool
Output point value
0=Off
1=On
3
Get/Set
Enable Diagnostics
Bool
Enables/Disables Diagnostics
(Channel diagnostics)
0=Disabled
1=Enabled
4
Get
Open load
Bool
Diagnostics Open Load
0=OK
1=Open Load
5
Get
Short Circuit / Overload
Bool
Diagnostics Short Circuit
0=OK
1=Short Circuit
6
Get/Set
Fault Action
Bool
Action taken on outputs value in
recoverable fault state
0=Fault Value Attribute
1=hold last state
7
Get/Set
Fault Value
Bool
Value for use with Fault Action
attribute
0=Off
1=On
8
Get/Set
Idle Action
Bool
Action taken on outputs value in idle
state
0=Idle Value Attribute
1=hold last state
9
Get/Set
Idle Value
Bool
Value for use with Idle Action
attribute
0=Off
1=On