TECHNICAL DATA

Fluid: Compressed air
Maximum pressure: 17 bar (250 psig)
Operating temperature*:  
-20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice  
formation at temperatures below +2°C (+35°F).
Partical removal: 5, 25 or 40 μm
Air quality: Within ISO 8573-1, Class 3 and 
Class 5 (particulates)
Typical flow with a 40 μm element at 6,3 bar 
(90 psig) inlet pressure and a 0,5 bar (7 psig) 
pressure drop: 190 dm

3

/s (403 scfm)

1/4 turn manual drain connection: 1/8” pipe 
thread
Automatic drain connection: 1/8” pipe thread
Automatic drain operating conditions (float 
operated): Bowl pressure required to close drain: 
Greater than 0,3 bar (5 psig)
Bowl pressure required to open drain:  
Less than 0,2 bar (3 psig)
Minimum air flow required to close drain:  
1 dm

3

/s (2 scfm)

Manual operation: Depress pin inside drain 
outlet to drain bowl
Nominal bowl size:  
0,5 litre (1 pint U.S.)
1 litre (1 quart U.S.)
Materials:
Body: Aluminium
Yoke: Aluminium
Bowl: Aluminium
Liquid level indicator: Pyrex
Element: Sintered bronze or polypropylene
Elastomers: Synthetic rubber 

REPLACEMENT ITEMS

Service kit (items circled on exploded view) 

4380-300

0.5 litre bowl liquid level lens (19 thru 27)  

4380-060

1 litre bowl liquid level lens (30 thru 38)  

4380-061

Bronze element KITS:
Filter element, 0,5 litre bowl, 5 µm (54, 55, 56) 

5576-197

Filter element, 0,5 litre bowl, 25 µm (54, 55, 56) 

5576-198

Filter element, 0,5 litre bowl, 40 µm (54, 55, 56) 

5576-199

Plastic element KITS:
Filter element, 0,5 litre bowl, 5 µm (53,55)   

 5576-97

Filter element, 0,5 litre bowl, 25 µm (53,55) 

  5576-98

Filter element, 0,5 litre bowl, 40 µm (53,55)   

5576-99

Filter element, 1 litre bowl, 5 μm (55) 

5311-01

Filter element, 1 litre bowl, 25 μm (55) 

5311-02

Filter element, 1 litre bowl, 40 μm (55) 

5311-03

Automatic drain, G1/8 outlet (49)  

3000-97

Automatic drain, 1/8 PTF outlet (49) 

3000-10

Manual drain, spindle type (44)  

684-84

Manual drain, 1/4 turn (40) 

619-50

Mechanical service life indicator (1)  

5797-50

Electrical service life indicator (6) 

4020-51R

INSTALLATION

1. Install yoke in air line - with air flow in direction  
  of arrow on top of yoke, upstream of  
  regulators, lubricators, and cycling valves, as  
  close as possible to the air supply when  
  filter is used as a main line filter, as close as  
  posible to the device being serviced when  
  filter is used as a final filter.
2. Connect piping to yoke ports using pipe  
  thread sealant on male threads only.
3. Lubricate o-rings (15) with a light coat of  
  o-ring grease, then place o-rings in grooves in  
  body (14).
4. Place clamp ring under lugs on top of yoke.
5. Make sure arrows on yoke and filter point in  
  same direction, then plug filter into yoke and  
  tighten clamp ring hand tight.
6. Turn bowl into body until arrowhead on bowl  
  is aligned with or to the right of the arrowhead  
  on the body.
7. Flexible tube with 3mm (0.125”) minimum I.D.  
  can be connected to the automatic drain.  
  Avoid restrictions in the

SERVICING

1. Open manual drain to expel accumulated  
  liquids. Keep liquids below baffle (53).
2. Clean or replace filter element when dirty,  
  when optional mechanical service life    
  indicator shows approximately all red, or  
  when optional electrical service life indicator  
  provides an electrical output.

DIASSEMBLY

1. Shut off inlet pressure. Reduce pressure in  
  inlet andoutlet lines to zero.
2. Unscrew the clamp ring and remove filter  
  from yoke.
3. Disassemble in general accordance with the  
  item numbers on exploded view. Do not  
  remove the drains or the service indicators  
  unless replacement is necessary. Remove  
  and replace only if they malfunction. Do not  
  attempt to remove rod (59), as it is cemented  
  to body. 
 
 

CLEANING

1. Clean lens (3, 24, 35) with warm water only.  
  Do not submerge electrical service indicator  

TECHNICAL FEATURES

Option selector

* See Norgren publication IM-900.920 for specifications and electrical wire connections of the optional electric service indicator.

Port

6 3/4“

8 1“ 

1 1/4“ 

1 1/2“

No yoke

Options

With mechanical service life indicator 

With electrical service life indicator* 

No service life indicator

Drain

A Automatic 

Closed bottom 

Manual, spindle type 

Manual, 1/4 turn

Bowl

1 litre (1 quart) no liquid indicator 

M  0,5 litre (1 pint) no liquid indicator  

0,5 litre (1 pint) with liquid indicator 

1 litre (1 quart) With liquid indicator

Thread

A PTF

ISO Rc tapered

ISO G parallel

No yoke

Element

5 µm 

25 µm 

40 µm

F68

˙

 – 

˙˙˙

 – 

˙˙˙

Bowl

E Long

G Standard 

29

32

32

31

30

36

37

35

31

30

33

39

34

33

38

18

28

19

25

26

24

21

22

19

21

20

20

23

22

27

53

55

56

54

2

5

3

4

7

10

11

12

13

15

14

57

1

6

8

9

58

59

41

43

42

40

46

45

47

44

48

51

50

49

52

Reviews: