TECHNICAL DATA
Fluid: Compressed air
Maximum pressure: 17 bar (250 psig)
Operating temperature*:
-20° to +80°C (0° to +175°F)
* Air supply must be dry enough to avoid ice
formation at temperatures below +2°C (+35°F).
Partical removal: 5, 25 or 40 μm
Air quality: Within ISO 8573-1, Class 3 and
Class 5 (particulates)
Typical flow with a 40 μm element at 6,3 bar
(90 psig) inlet pressure and a 0,5 bar (7 psig)
pressure drop: 190 dm
3
/s (403 scfm)
1/4 turn manual drain connection: 1/8” pipe
thread
Automatic drain connection: 1/8” pipe thread
Automatic drain operating conditions (float
operated): Bowl pressure required to close drain:
Greater than 0,3 bar (5 psig)
Bowl pressure required to open drain:
Less than 0,2 bar (3 psig)
Minimum air flow required to close drain:
1 dm
3
/s (2 scfm)
Manual operation: Depress pin inside drain
outlet to drain bowl
Nominal bowl size:
0,5 litre (1 pint U.S.)
1 litre (1 quart U.S.)
Materials:
Body: Aluminium
Yoke: Aluminium
Bowl: Aluminium
Liquid level indicator: Pyrex
Element: Sintered bronze or polypropylene
Elastomers: Synthetic rubber
REPLACEMENT ITEMS
Service kit (items circled on exploded view)
4380-300
0.5 litre bowl liquid level lens (19 thru 27)
4380-060
1 litre bowl liquid level lens (30 thru 38)
4380-061
Bronze element KITS:
Filter element, 0,5 litre bowl, 5 µm (54, 55, 56)
5576-197
Filter element, 0,5 litre bowl, 25 µm (54, 55, 56)
5576-198
Filter element, 0,5 litre bowl, 40 µm (54, 55, 56)
5576-199
Plastic element KITS:
Filter element, 0,5 litre bowl, 5 µm (53,55)
5576-97
Filter element, 0,5 litre bowl, 25 µm (53,55)
5576-98
Filter element, 0,5 litre bowl, 40 µm (53,55)
5576-99
Filter element, 1 litre bowl, 5 μm (55)
5311-01
Filter element, 1 litre bowl, 25 μm (55)
5311-02
Filter element, 1 litre bowl, 40 μm (55)
5311-03
Automatic drain, G1/8 outlet (49)
3000-97
Automatic drain, 1/8 PTF outlet (49)
3000-10
Manual drain, spindle type (44)
684-84
Manual drain, 1/4 turn (40)
619-50
Mechanical service life indicator (1)
5797-50
Electrical service life indicator (6)
4020-51R
INSTALLATION
1. Install yoke in air line - with air flow in direction
of arrow on top of yoke, upstream of
regulators, lubricators, and cycling valves, as
close as possible to the air supply when
filter is used as a main line filter, as close as
posible to the device being serviced when
filter is used as a final filter.
2. Connect piping to yoke ports using pipe
thread sealant on male threads only.
3. Lubricate o-rings (15) with a light coat of
o-ring grease, then place o-rings in grooves in
body (14).
4. Place clamp ring under lugs on top of yoke.
5. Make sure arrows on yoke and filter point in
same direction, then plug filter into yoke and
tighten clamp ring hand tight.
6. Turn bowl into body until arrowhead on bowl
is aligned with or to the right of the arrowhead
on the body.
7. Flexible tube with 3mm (0.125”) minimum I.D.
can be connected to the automatic drain.
Avoid restrictions in the
SERVICING
1. Open manual drain to expel accumulated
liquids. Keep liquids below baffle (53).
2. Clean or replace filter element when dirty,
when optional mechanical service life
indicator shows approximately all red, or
when optional electrical service life indicator
provides an electrical output.
DIASSEMBLY
1. Shut off inlet pressure. Reduce pressure in
inlet andoutlet lines to zero.
2. Unscrew the clamp ring and remove filter
from yoke.
3. Disassemble in general accordance with the
item numbers on exploded view. Do not
remove the drains or the service indicators
unless replacement is necessary. Remove
and replace only if they malfunction. Do not
attempt to remove rod (59), as it is cemented
to body.
CLEANING
1. Clean lens (3, 24, 35) with warm water only.
Do not submerge electrical service indicator
TECHNICAL FEATURES
Option selector
* See Norgren publication IM-900.920 for specifications and electrical wire connections of the optional electric service indicator.
Port
6 3/4“
8 1“
A
1 1/4“
B
1 1/2“
N
No yoke
Options
D
With mechanical service life indicator
E
With electrical service life indicator*
N
No service life indicator
Drain
A Automatic
E
Closed bottom
M
Manual, spindle type
Q
Manual, 1/4 turn
Bowl
C
1 litre (1 quart) no liquid indicator
M 0,5 litre (1 pint) no liquid indicator
R
0,5 litre (1 pint) with liquid indicator
U
1 litre (1 quart) With liquid indicator
Thread
A PTF
B
ISO Rc tapered
G
ISO G parallel
N
No yoke
Element
1
5 µm
2
25 µm
3
40 µm
F68
˙
–
˙˙˙
–
˙˙˙
Bowl
E Long
G Standard
29
32
32
31
30
36
37
35
31
30
33
39
34
33
38
18
28
19
25
26
24
21
22
19
21
20
20
23
22
27
53
55
56
54
2
5
3
4
7
10
11
12
13
15
14
57
1
6
8
9
58
59
41
43
42
40
46
45
47
44
48
51
50
49
52