IMI NORGREN 54D Operation Manual Download Page 15

 
 
 

 

15 

Electronic Pressure Sensor 54D

 

Operation manual

 

7503761000000050 05/2019 

9.3.2 Set damping for the switching outputs 

 Select [dAP] and set the value. 

dAP value = response time between pressure change and change of the 
switching status in milliseconds. 

The following fixed values can be set; they define the switching frequency (f in 
Hz) of the output: 

dAP  6 

10 

30 

60 

100  250  500  1000 

2000 

80 

50 

16 

0,5 

0,25 

 

 

 

 

9.3.3 Configuration of the display 

 Select [diS] and set the update rate and orientation of the display: 

[d1]: update of the measured values every 50 ms. 

[d2]: update of the measured values every 200 ms. 

[d3]: update of the measured values every 600 ms. 

[Ph]: display of the pressure peaks remains for a short time (peak hold). 

[rd1], [rd2], [rd3]: display as for d1, d2, d3; rotated by 180°. 

[OFF]: the display is switched off in the operating mode

 

 Select [cLor] and define the colour of the digital display: 

[r-on]: display = red if output 1 is switched; display = green if output 1 is not 
switched. 

[G-on]: display = green if output 1 is switched; display = red if output 1 is not 
switched. 

[red]: the colour of the display is red / does not change. 

   [Gren]: the colour of the display is green / does not change.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for 54D

Page 1: ...Operation manual 54D xxxxx DD0 xx 2 x PNP Electronic Pressure Sensor 54D...

Page 2: ...onnection 8 7 Operating and display elements 9 8 Menu 10 8 1 Menu structure 10 8 2 Explanation of the menu 11 9 Parameter setting 12 9 1 Parameter setting in general 12 9 2 Set output signals 14 9 2 1...

Page 3: ...00000050 05 2019 9 4 Service functions 17 9 4 1 Read min max values for the system pressure 17 9 4 2 Reset all parameters to factory setting 17 10 Operation 17 10 1 Read set parameters 17 10 2 Error i...

Page 4: ...res The unit monitors the system pressure differential pressure in compressed air networks and pneumatic systems of machines and plants Avoid static and dynamic overpressure exceeding the specified ov...

Page 5: ...s switching state if it is above or below the set switching limits SP1 rP1 The following switching functions can be selected Hysteresis function normally open ou1 Hno fig 1 Hysteresis function normall...

Page 6: ...n Before installing and removing the unit Make sure that no pressure is applied to the system Screw the pressure connection or adapter G1 8 to the main pressure connection 1 and tighten Maximum tighte...

Page 7: ...th the M4 x 35 screws 2 to the flange Maximum tightening torque 0 5 Nm Hook the unit into the DIN rail and clip it into place Removal Lever out the mounting clip with a screwdriver at the top or at th...

Page 8: ...national and international regulations for the installation of electrical equipment must be adhered to Voltage supply according to EN 50178 SELV PELV Disconnect power Connect the unit as follows Pin 1...

Page 9: ...label LEDs 5 6 not used LED 7 8 switching status of the corresponding output 9 Alphanumeric display 4 digits Display of the current system pressure Indication of the parameters and parameter values 10...

Page 10: ...10 Electronic Pressure Sensor 54D Operation manual 7503761000000050 05 2019 8 Menu 8 1 Menu structure...

Page 11: ...Switching signal for the pressure limit values hysteresis function H or window function F either normally open no or normally closed nc ou2 Output function for OUT2 Switching signal for the pressure l...

Page 12: ...he IO Link interface 1 2 3 Select parameter Press Mode Enter until the requested parameter is displayed Set parameter value Press Set and keep it pressed Current setting value of the parameter flashes...

Page 13: ...is displayed for 15 s if you try to change parameter values For unlocking Press Mode Enter Set for 10 s uLoc is displayed On delivery not locked Timeout Press Mode Enter until EF is displayed If the...

Page 14: ...9 2 4 Set the switching limits window function Make sure that for ou1 the function Fno or Fnc is set Select FH1 and set the upper limit of the acceptable range Select FL1 and set the lower limit of t...

Page 15: ...te and orientation of the display d1 update of the measured values every 50 ms d2 update of the measured values every 200 ms d3 update of the measured values every 600 ms Ph display of the pressure pe...

Page 16: ...c adjustment of the offset in the range 0 bar 2 of the measuring span Make sure that there is no system pressure or that there is a differential pressure of 0 bar or that it is as close as possible to...

Page 17: ...s output signals according to the set parameters Operation indication chapter 7 Operating and display elements 10 1 Read set parameters Press Mode Enter until the requested parameter is displayed Brie...

Page 18: ...10 00 0 95 9 95 0 05 kPa 90 1000 95 995 5 PSI 13 145 14 144 1 inHG 26 296 28 294 2 PQ7809 54D V101 DD0 AA PQ7834 54D V110 DD0 AA 11 Factory setting Werkseinstellung Benutzer Einstellung Kommentare SP...

Page 19: ...19 Electronic Pressure Sensor 54D Operation manual 7503761000000050 05 2019...

Page 20: ...ligation of own judgement and verification It must be remembered that our products are subject to a natural process of wear and aging This document as well as the data specifications and other informa...

Reviews: